EasyManua.ls Logo

Omron E3X-NA User Manual

Omron E3X-NA
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
A-64 Photoelectric Sensors
Super Manual Fiber Amplifier
E3X-NA
Adjuster type standard that is the culmina-
tion of true ease and simplicity
Features
Instinctive LED bar displays of light levels
The previous manual type used the stability and incident level
indicators to display the light level change, which was difficult
to understand at a glance. The E3X-NA uses the LED bars to
display the light level, ensuring the light level change at a
glance.
Same "Wire-saving" Connector as
E3X-DA-N
OMRON's original wiring-saving connector, which was inher-
ited from the digital fiber amplifier E3X-DA-N, allows connec-
tion of up to 16 units.
* The vertical movement
of the LED light level
and operation display
shows the light level
at a glance.
Operation indicator
Approx. 20% or lower
Approx. 10% or lower
Approx. -10% or higher
Approx. -20% or higher
Unstable level
E3X-NA Conventional model
Power supply
pin
Optical
commu-
nications
Master connector
Slave connector
Gang-mount up
to 16 Amplifiers
Question and Answer IconNeed help?

Do you have a question about the Omron E3X-NA and is the answer not in the manual?

Omron E3X-NA Specifications

General IconGeneral
BrandOmron
ModelE3X-NA
CategoryAmplifier
LanguageEnglish

Summary

Features of Super Manual Fiber Amplifier E3X-NA

Instinctive LED Bar Displays of Light Levels

Uses LED bars to display light level changes for quick understanding.

Wire-Saving Connector for Amplifier Units

Inherited wiring-saving connector allows connection of up to 16 units.

Reduced Wiring and Space for Power Lines

Example showing reduced wiring and space for 5 amplifiers.

Optical Communications for Mutual Interference Prevention

Optical communication prevents mutual interference between amplifiers.

Consistent Sensing Distance Compared to Previous Models

Compares sensing distance to previous models, showing consistency.

Design and Dimensions Inherited from E3X-DA-N

Highlights shared dimensions and design elements with E3X-DA-N.

Seven Times Improvement in Detection Accuracy

Details improved detection accuracy compared to previous models.

Series Expansion with High-Speed and Waterproof Types

Mentions expansion of the series with new types.

Ordering Information for Amplifier Units

Pre-wired Amplifier Unit Models

Lists pre-wired amplifier unit models by type.

Connector Type Amplifier Unit Models

Lists connector type amplifier units by model and connection.

Amplifier Unit Connectors (Sold Separately)

Details available connectors for amplifier units.

Connector Type Ordering Precautions

Guidance on how to order amplifier units and connectors.

Sensor I/O Connectors (Sold Separately)

Lists available sensor I/O connectors.

Other Accessories (Sold Separately)

Lists other accessories like mounting brackets and end plates.

Applicable Fiber Unit Types

Long Distance Fiber Units

Details long-distance fiber unit specifications.

General Purpose Fiber Units

Lists general-purpose fiber unit specifications.

Small Diameter Head Fiber Units

Specifications for small diameter head fiber units.

Flexible (Resists Breaking) Fiber Units (R4)

Fiber units designed for flexibility and resistance to breaking.

Side-View Fiber Units

Specifications for side-view fiber units.

Chemical Resistant Fiber Units

Details specifications for chemically resistant fiber units.

Heat Resistant Fiber Units

Lists specifications for heat-resistant fiber units.

Grooved Fiber Units

Specifications for grooved fiber units.

Narrow Vision Field Fiber Units

Details specifications for narrow vision field fiber units.

Area Sensing Fiber Units

Specifications for area sensing fiber units.

Long Distance Fiber Units (Additional Specifications)

Specifications for long-distance fiber units.

General Purpose Fiber Units (Additional Specifications)

Lists general-purpose fiber unit specifications.

Thin Fiber Units

Specifications for thin fiber units.

Flexible Fiber Units (Additional Specifications)

Fiber units designed for flexibility and resistance to breaking.

Coaxial Fiber Units

Specifications for coaxial fiber units.

Side-View Fiber Units (Additional Specifications)

Specifications for side-view fiber units.

Chemical Resistant Fiber Units (Additional Specifications)

Details specifications for chemically resistant fiber units.

Heat Resistant Fiber Units (Additional Specifications)

Lists specifications for heat-resistant fiber units.

Area Sensing Fiber Units (Additional Specifications)

Specifications for area sensing fiber units.

Retroreflective Fiber Units

Specifications for retroreflective fiber units.

Limited Reflective Fiber Units

Details specifications for limited reflective fiber units.

Fluid Level Detection Fiber Units

Specifications for fluid level detection fiber units.

Rating and Performance Specifications

Amplifier Unit Performance

Performance specifications for amplifier units.

Amplifier Unit Connector Performance

Performance specifications for amplifier unit connectors.

Output Circuit Diagrams

NPN Output Circuit Diagrams

Output circuit diagram for NPN output models.

PNP Output Circuit Diagrams

Output circuit diagram for PNP output models.

Amplifier Unit Nomenclature and Precautions

Amplifier Unit Operation Indicators

Explains the operation indicators and modes.

Amplifier Unit Precautions and Mounting

Covers correct use, design, mounting, and operating environment.

Fiber Unit Installation and Connection

Fiber Unit Installation Guide

Instructions for installing fiber units, including tightening force.

Fiber Connection and Disconnection Procedures

Procedures for connecting and disconnecting fiber units.

Fiber Unit Connection Guidelines

Guidelines for connecting fiber units, bending radius, and vibration prevention.

E39-F11 Sleeve Bender Usage

Instructions for using the sleeve bender tool.

Amplifier Unit Connector Installation and Removal

Instructions for installing and removing amplifier unit connectors.

Accessories

Mounting End Plate (PFP-M)

Instructions for mounting end plates.

E39-R3 Reflector Usage

Guidance on using the E39-R3 reflector.

E39-F32 Protective Spiral Tubes

Instructions for using protective spiral tubes with fibers.

E39-F10 Fiber Connector Fitting

Procedure for fitting the E39-F10 fiber connector.

Dimensions (Unit: mm)

Pre-wired Amplifier Unit Dimensions

Dimensional drawings for pre-wired amplifier units.

Water-Resistant Amplifier Unit Dimensions

Dimensional drawings for water-resistant amplifier units with cables.

Connector Type Amplifier Unit Dimensions

Dimensional drawings for connector type amplifier units.

M8 Connector Water-Resistant Unit Dimensions

Dimensional drawings for M8 connector water-resistant amplifier units.

Amplifier Unit Connectors

Master Connector E3X-CN11 Specifications

Dimensions and specifications for the master connector.

Slave Connector E3X-CN12 Specifications

Dimensions and specifications for the slave connector.

Related product manuals