A-74 Photoelectric Sensors
Area sensing
* The sensing distance is 100 mm and the value can be detected in each detection area. (The sensing object diameter is the value in stationary status.)
Features Shape
Compatible
Amplifier
Units (E3X-)
Sensing distance (mm)
(Values in parentheses: when
using the E39-F1 Lens Unit)
Standard object (mm)
Minimum sensing object
(Opaque object) Typical
Model
Permissible
bending
radius
Multi-point de-
tection (4 head)
NA#(V)
2.0 mm dia.
(0.03 mm dia.)
E32-M21
25 mm
NA#F
2.0 mm dia.
(0.3 mm dia.)
Detects in a 30
mm area
NA#(V)
(0.5 mm dia.) *
E32-T16W
10 mm
NAG#
NA#F (4.0 mm dia.) *
Detects in a 30
mm area
NA#(V) (0.5 mm dia.) *
E32-T16WR
1 mm
NA#F (4.0 mm dia.) *
Side-view type
Ideal for appli-
cations that do
not have suffi-
cient depth
NA#(V)
(0.3 mm dia.) *
E32-T16J
10 mm
NAG#
NA#F (2.0 mm dia.) *
Side-view type
Ideal for appli-
cations that do
not have suffi-
cient depth
NA#(V) (0.3 mm dia.) *
E32-T16JR
1 mm
NA#F (2.0 mm dia.) *
Detection in
area of 10 mm
width, long dis-
tance
NA#(V)
(0.9 mm dia.) *
E32-T16
25 mm
NAG#
NA#F (1.5 mm dia.) *
Stable detec-
tion of small
work in wide
area Protective
structure: IEC
60529 IP50
NA#(V)
(0.3 mm dia.) *
E32-T16P
10 mm
NAG#
NA#F (2.0 mm dia.) *
Stable detec-
tion of small
work in wide
area Protective
structure: IEC
60529 IP50
NA#(V) (0.3 mm dia.) *
E32-T16PR
1 mm
NA#F (2.0 mm dia.) *
M3 screw
300
90
Free-cut
30mm
920
170
270
Free-cut
30mm
690
200
Free-cut
11mm
520
95
150
Free-cut
11mm
390
110
Free-cut
10mm
1,500
275
450
Free-cut
11mm
600
110
180
Free-cut
11mm
450
130

Related product manuals