EasyManua.ls Logo

Omron E3X-DA-N Datasheet

Omron E3X-DA-N
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
E3X-DA-N
A-419E3X-DA-N
Digital Fiber Amplifier
E3X-DA-N
Truly ultimate fiber amplifier
in pursuit of "user friendliness"
and "high performance"
UL991*
Features
Reducing power line wiring meaning
space is saved. New design for easier
maintenance.
The connector type that uses the wire-saving connector sup-
plies power to the single-conductor slave connectors via the
three-conductor master connector. Hence, the following three
has been made possible.
1. Wiring is much simpler.
2. Relay connectors are not required meaning that space is used
more efficiently and costs are reduced.
3. Simple inventory control because of no differentiation between
master and slave in the amplifier section.
Super digital display by use of the Auto
Power Control (APC) circuit
The incident level of LEDs used in sensors is prone to deteriorate
with time and as a result, detection becomes unstable.
Using the APC (auto power control) circuit for the first time as the
fiber sensor, the E3X-DA-N series has no digital value variations,
realizing severe detection.
This makes the E3X-DA-N ideal for applications where a high de-
gree of sensitivity is required, such as detecting crystal glass.
Industry First Patent pending
Master Connector
New Connector Design
Power supply pin
Slave Connector
Up to 16 Amplifiers
can be connected together.
Optical
commu-
nications
Industry First
Incident level
Time
Threshold
3000
Detection becomes unstable
Incident level
Time
Threshold
3000
Stable detection
Conventional
Digital Fiber
Amplifiers
E3X-DA-N Series
* UL-listed including UL991 tests/evaluations Applicable standard: UL3121-1 Standards for additional tests/evaluations
for applications: UL991, SEMI S2-0200

Other manuals for Omron E3X-DA-N

Question and Answer IconNeed help?

Do you have a question about the Omron E3X-DA-N and is the answer not in the manual?

Omron E3X-DA-N Specifications

General IconGeneral
Output Current100 mA max.
Degree of ProtectionIP67
TypeFiber Amplifier
Output TypeNPN
Supply Voltage12 to 24 VDC
Current Consumption40 mA max.
Sensing DistanceVaries with fiber unit
Residual Voltage1 V max.
Light SourceRed LED
IndicatorLED
Protection CircuitReverse polarity protection
Operating Temperature-25 to 55°C
Storage Temperature-40 to 70 °C
Ambient Humidity35 to 85% RH
Vibration Resistance10 to 55 Hz, 1.5 mm
Shock Resistance500 m/s²
Housing MaterialABS
Connection2 m cable

Related product manuals