EasyManua.ls Logo

Omron E5CC-RX2ABM-000 - User Manual

Omron E5CC-RX2ABM-000
139 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Looking for a discount?
Check out our current promotions!
This coversheet was created by Verical, a division of Arrow Electronics, Inc. (“Verical”). The attached document was created by the part supplier,
not Verical, and is provided strictly 'as is.' Verical, its subsidiaries, affiliates, employees, and agents make no representations or warranties
regarding the attached document and disclaim any liability for the consequences of relying on the information therein. All referenced brands,
product names, service names, and trademarks are the property of their respective owners.
00000005981LF-000
EOS Power
Buy Now
We have 45,000 LP502030-PCM-NTC-LD-A02554 - EEMB - Lithium Battery Rectangular 3.7V 250mAh Rechargeable in
stock now. Starting at $0.034. This EEMB part is fully warrantied and traceable.
1-855-837-4225
Give us a call
International: 1-555-555-5555
1-415-281-3866
1-415-281-3866
Arrow Electronics,
Verical Division
P.O. Box 740970
Los Angeles, CA 90074-0970
Arrow Electronics, Inc
9201 East Dry Creek Road
Centennial, CO 80112
E5CC-RX2ABM-000
OMRON
Buy Now

Questions and Answers

  • M
    Michael BrewerSep 14, 2025
    What to do if the SP is being held on my Omron E5CC-RX2ABM-000?
    • S
      smithmatthewSep 14, 2025
      If the SP is being held on your Omron Temperature Controller, check the HOLD indicator. If it is lit, change the Hold parameter to OFF.
  • C
    Courtney DuffyNov 19, 2025
    How to fix communication errors with Omron Temperature Controller?
    • T
      Tracie PhillipsNov 19, 2025
      If you are unable to establish communication or are encountering communication errors with your Omron Temperature Controller, there are several potential causes. Ensure the communications wiring is correct and securely connected, and that the cable is not broken or excessively long (the total cable length for RS-485 should be 500 m max). Verify that you are using a shielded, AWG24 to AWG18 twisted-pair cable. If using 1:N communications, ensure no more than 32 nodes are connected, including the host. Confirm that terminating resistance is set at each end of the line. Ensure the Controller is receiving the specified power supply voltage. All devices on the communications line must use the same baud rate, protocol, data length, stop bits, and parity. Check the host device programming with a ...

Omron E5CC-RX2ABM-000 Specifications

General IconGeneral
TypeDigital Temperature Controller
ModelE5CC-RX2ABM-000
Power Supply100 to 240 VAC
Size48 x 48 mm
Number of Outputs2
Control Output 1Relay
Mounting MethodPanel Mount
Number of Control Outputs1
Setting Resolution0.1 °C
Protection RatingIP66
Input TypeThermocouple, RTD
Output TypeRelay, Voltage
Display TypeLCD
Control MethodPID
Alarm OutputRelay