E8F
E8F
3
Note: 1.
Negative-pressure model
2. Refer
 to the following for the operation modes
 available
at
 the time of initial settings.
Hysteresis Mode
Pressure valve
OFF set value ON set value
Output
0.98Mp
a
 
98 kP
a
 
–101 kP
a
 
10
 kgf/cm
2
 
1kgf/cm
2
 
–76cmHg
In the above, the ON point is set larger than the OFF
point.
Wind
 Mode
Pressure valve
ON set value OFF set value
Output
0.98Mp
a
 
98 kP
a
 
–101 kP
a
 
10
 kgf/cm
2
 
1kgf/cm
2
 
–76cmHg
In the above, the ON point is set smaller than the OFF
point.
3. The 2
1
/
2
-digit display refers to a display in which the
third
 digit displays only 0 or 1.
0 or 1
0 to 9 0 to 9
Third digit
Second digit First digit
 Characteristics
Voltage
 influence
±
1.5% FS max.
T
emperature influence
±
3% FS max.
Degree of protection
IEC IP66
Dielectric strength
1,000 V
AC for 1 min
Insulation resistance
100 M
Ω
 min. (at 500 VDC) between current carry parts and case
V
ibration resistance
Destruction: 10 to 500 Hz, 1.5-mm double amplitude or 100 m/s
2
 (approx. 10G) for 2 hours
each in X, Y
, and Z directions
Shock resistance
Destruction: 500 m/s
2
 (approx. 50G) 2 times each in X, Y
, and Z directions.
Pressure port R(PT) 1/8 taper screw and M5 x P0.8 female screw for zinc die-cast pressure port
Cord
2-m-long UL-approved cord
Weight
60 g (excluding cord)