Chapter 1
1-4
Communications Methods
Applicable Line Wire Size, Terminal Screws, and Torque
Note For details on solderless terminal sizes and wiring methods, refer to the User's Manual.
Wiring Diagram
Note For information on wiring between the USB/RS-485 or RS-232C/RS-485 Converter and the
host computer, refer to the manual for the Converter.
Communications Parameters
With 3G3JE Communications Models (RS-485), communications parameters (communications unit
number, baud rate, data length, stop bits, and parity) can be set. The following table shows the com-
munications parameters and their setting ranges.
Terminal
screw size
Torque Wire type Wire size Recommended
wire size
Cable
M3 0.5 to 0.6 N·m Stranded wire
0.2 to 1.5 mm
2
(AWG24 to
AWG16)
0.75 mm
2
(AWG18)
Shielded twisted-pair
cable
Item Parameter No. Settings Default
Communications unit number P15 0 to 99 1
Communications baud rate P16 2.4, 4.8, 9.6, or 19.2 kbps 9.6 kbps
Communications data length P17 7 or 8 bits 7 bits
Communications stop bits P18 1 or 2 bits 2 bits
Communications parity P19 None, even, or odd Even
FG
+
SG
RS-485
RS-485
Terminal No. Signal
RS-485 (+)
RS-485 ()
RS-485 (+)
RS-485 ()
A
B
Host computer
RS-232C/USB
Inverter 3G3JE -A2001-FLK
-A2002B-FLK
-A2004B-FLK
3G3JE node
at end of line
RS-485
Shield
Shield
120
(1/2 W)
Terminator
Use a 120 (1/2 W) terminator.
Terminal No.
Signal
A
B
USB/RS-485 or
RS-232C/RS-485
Converter
Signal
Communi-
cations
terminals
Communi-
cations
terminals