Chapter 2
2-13
CompoWay/F Communications Procedures
1.Test Data
Set between 0 and 23 bytes of user-defined test data.
Set a value for the test data within the ranges shown below according to the communications data
length.
Note Do not set the value H'40. No response will be returned if this value is included.
2.Response Code
Normal Completion
Error Completion
■ Operation Command
The commands supported by the 3G3JE are listed in the following table. Refer to this table for com-
mand codes and related information.
Service Request PDU
Service Response PDU
Communications data length Test Data
8 bits ASCII data: H'20 to H'7E or H'A1 to H'FE
7 bits ASCII data: H'20 to H'7E
Response code Name Description
0000 Normal completion No errors were found.
Response code Error name Description
1001 Command too long The command is too long.
2203 Operation error CPU or EEPROM error
MRC
30
2222
05
SRC
Command
code
Related
information
MRC
30
22 4
05
SRC
Response code