    Mr. Steven JohnsonAug 20, 2025
    What to do if Omron SYSDRIVE 3G3JV motor stops during acceleration?
    • N
      nespinozaAug 20, 2025
      If the motor stops during acceleration or when a load is connected to your Omron Inverter, the load might be too big. Try lengthening the acceleration time or reducing the load. You might also need to increase the motor capacity.
  • W
    woodardmatthewAug 22, 2025
    What to do if Omron SYSDRIVE 3G3JV Inverter is not in RUN mode?
    • R
      Ryan LunaAug 22, 2025
      If your Omron Inverter isn't in RUN mode, cancel the RUN command, then press the Mode Key to change the Inverter's mode. Restart the Inverter when the green indicator is lit.
  • E
    ewagnerAug 25, 2025
    Why Omron SYSDRIVE 3G3JV Inverter motor does not operate with correct frequency reference?
    • J
      Jessica ReyesAug 25, 2025
      If the motor does not operate with input through the control circuit terminals on your Omron Inverter and the frequency reference is zero or different from the set value, check that the setting in n03 for frequency reference selection coincides with the actual method of giving frequency instructions.
  • D
    Dr. Ricky PettyAug 26, 2025
    Why display does not change when Increment or Decrement Key is pressed on Omron Inverter?
    • I
      ijohnsonAug 26, 2025
      If the display doesn't change when you press the Increment or Decrement Key on your Omron Inverter, it could be due to parameter write-prohibit being active. Set n01 to an appropriate value according to the parameter you want to set. Alternatively, the Inverter might be operating. Turn the Inverter off before making any settings.
  • D
    Deanna SnyderAug 28, 2025
    How to enable reverse rotation on Omron SYSDRIVE 3G3JV Inverter?
    • S
      scottrojasAug 28, 2025
      If your Omron Inverter motor only rotates in one direction, reverse rotation-prohibit might be selected. To enable both forward and reverse rotation, set n05 to 0.
  • M
    moorekathrynAug 30, 2025
    What to do if preset output frequency exceeds the upper-limit frequency on Omron SYSDRIVE 3G3JV Inverter?
    • L
      Latasha WilliamsAug 30, 2025
      If the preset output frequency exceeds the upper-limit frequency on your Omron Inverter, make sure that the parameters in n09 and n30 are correct.
  • R
    Robert VegaSep 1, 2025
    How to raise the frequency reference on Omron SYSDRIVE 3G3JV Inverter?
    • K
      kathryn40Sep 1, 2025
      If the frequency reference is too low on your Omron Inverter, raise the frequency reference to at least the minimum output frequency.
  • D
    derekericksonSep 3, 2025
    What to do if Omron SYSDRIVE 3G3JV Inverter has incorrect sequence input?
    • S
      Shannon LiuSep 3, 2025
      If you're inputting a 2-wire sequence while 3-wire sequence is in effect (or vice versa) on your Omron Inverter, check and correct the setting in n37 or change the input method of the RUN command.
  • C
    christian33Sep 5, 2025
    What to do if the load is too big for Omron SYSDRIVE 3G3JV?
    • C
      Cynthia MolinaSep 5, 2025
      If the load is too big for your Omron Inverter, reduce the load amount by either reducing the load or lengthening the acceleration/deceleration time.
  • D
    Dr. Nina Logan DDSSep 7, 2025
    What to do if Omron SYSDRIVE 3G3JV Inverter ambient temperature is too high?
    • E
      elizabeth04Sep 7, 2025
      If the ambient temperature is too high for your Omron Inverter, lower the ambient temperature of the motor to within the acceptable ambient operating temperature range.

Omron SYSDRIVE 3G3JV Series Specifications

General IconGeneral
ModelSYSDRIVE 3G3JV Series
CategoryInverter
Output Frequency Range0.1 to 400Hz
Frequency Range50/60Hz
Control MethodPWM Control
Overload Capacity150% for 1 minute
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Cooling MethodFan Cooling
Ambient Temperature-10 to 50°C
Operating Temperature-10 to 50°C
Storage Temperature-20°C to +65°C
Humidity90% RH or less (non-condensing)
Altitude1000m or less
Vibration5.9 m/s² or less
Braking UnitBuilt-in
CommunicationRS-485
Voltage Class200V class, 400V class
Input Voltage3-phase 200 to 240V AC, 3-phase 380 to 480V AC