5-17
5-7 Selecting the Reverse Rotation-prohibit
This
parameter is used to specify whether to enable or disable the
reverse
rotation
command sent to the Inverter from
the control circuit terminals or
Digital
Operator
.
The
parameter should be set to “not accept” when the Inverter is applied to
systems that prohibit the reverse rotation of the Inverter.
H Selecting the Reverse Rotation-prohibit (n05)
n05 Reverse Rotation-prohibit Selection Changes during
operation
No
Setting
range
0, 1 Unit of
setting
1 Default setting 0
Set Values
Value Description
0 Accept
1 Not accept
Basic Operation Chapter
5

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSDRIVE 3G3JV Series and is the answer not in the manual?

Omron SYSDRIVE 3G3JV Series Specifications

General IconGeneral
ModelSYSDRIVE 3G3JV Series
CategoryInverter
Output Frequency Range0.1 to 400Hz
Frequency Range50/60Hz
Control MethodPWM Control
Overload Capacity150% for 1 minute
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat
Cooling MethodFan Cooling
Ambient Temperature-10 to 50°C
Operating Temperature-10 to 50°C
Storage Temperature-20°C to +65°C
Humidity90% RH or less (non-condensing)
Altitude1000m or less
Vibration5.9 m/s² or less
Braking UnitBuilt-in
CommunicationRS-485
Voltage Class200V class, 400V class
Input Voltage3-phase 200 to 240V AC, 3-phase 380 to 480V AC