Chapter 3
3-2
Communications Data
3-1 Variable Area Setting Range List
The following table lists the data ranges for each type of variable. Refer to the individual items for
details.
● Variable Type C0
● Variable Type C1
• The unit for the frequency reference, output frequency, output current, accumulated operating time,
frequency references 1 to 4, acceleration time, and deceleration time is 0.1.
Examples:
0.7
→ H’00000007
50.0
→ H’000001F4
120 (120.0)
→ H’000004B0
• The frequency reference range depends on the frequency reference upper limit and the frequency
reference lower limit.
• The acceleration time, deceleration time, and application selection cannot be written during opera-
tion. (They can be read during operation.)
• 1 kh = 1,000 hours
Address Name Setting range Communications notation Default Unit
0000 Frequency reference 0.0 to 120 H’00000000 to H’000004B0 10.0 Hz
0001 Output frequency --- H’00000000 to H’000004B0 --- Hz
0002 Output current --- H’00000000 to H’00000032 --- A
0003 Accumulated operat-
ing time
--- H’00000000 to H’000003E7 --- kh
0004 Status --- --- --- ---
Address Name Setting range Communications notation Default Unit
0000 Frequency reference 0.0 to 120 H’00000000 to H’000004B0 10.0 Hz
0001 Frequency reference 1 H’00000000 to H’000004B0 10.0 Hz
0002 Frequency reference 2 H’00000000 to H’000004B0 0.0 Hz
0003 Frequency reference 3 H’00000000 to H’000004B0 0.0 Hz
0004 Frequency reference 4 H’00000000 to H’000004B0 0.0 Hz
0005 Acceleration time 0.1 to 999 H’00000001 to H’00002706 10.0 s
0006 Deceleration time 0.1 to 999 H’00000001 to H’00002706 10.0 s
0007 Application selection 0: Fan applica-
tion or pump
application
1: Conveyor
application
H’00000000
H’00000001
1 ---