Series FH-3000 Series FH-1000 Series
Type Standard Controller(4 cores) Standard Controller(2 cores)
Model FH-3050
FH-3050-
10
FH-3050-
20
FH-1050
FH-1050-
10
FH-1050-
20
Current
consump-
tion
When connecting
an intelligent com-
pact digital camera
When connecting
the following light-
ing or lighting con-
trollers without an
external power sup-
ply
- FL
V-TCC1
- FLV-TCC4
- FLV-TCC3HB
- FLV-TCC1EP
- FL-TCC1
When connecting
the following light-
ing or lighting con-
trollers
- FL-TCC1PS
- FL-MD£MC
5.0A
max.
7.0A
max.
11.5A
max.
4.7A
max.
6.5A
max.
10.9A
max.
Other than above 4.1A
max.
4.8A
max.
6.8A
max.
3.6A
max.
4.3A
max.
6.2A max.
Built-in FAN Yes
Usage
Environ-
ment
Ambient temperature
range
Operating: 0°C to +50°C
Storage: -20 to +65°C (with no icing or condensation)
Ambient humidity
range
Operating and storage: 35 to 85% (with no condensation)
Ambient atmosphere No corrosive gases
Vibration tolerance Oscillation frequency: 10 to 150 Hz, Half amplitude: 0.1 mm, Accelera-
tion: 15 m/s
2
Sweep time: 8 minute/count, Sweep count: 10, V
ibration direction: up
and down/front and behind/left and right
Shock resistance
Impact force: 150 m/s
2
T
est direction: up and down/front and behind/left and right
Noise im-
munity
Fast
T
ransient
Burst
DC power:
Direct infusion: 2 kV
, Pulse rising: 5 ns, Pulse width: 50 ns, Burst
continuation time: 15 ms/0.75 ms, Period: 300 ms, Application time:
1 min.
I/O line:
Direct infusion: 1 kV, Pulse rising: 5 ns, Pulse width: 50 ns, Burst
continuation time: 15 ms/0.75 ms, Period: 300 ms, Application time:
1 min.
Grounding
Class D grounding (100 Ω or less grounding resistance)
*2
3 Configuration
3-9
FH Series Vision System Hardware Setup Manual (Z366-E1)
3-1 Sensor Controller
3
3-1-1 FH-1000/2000/3000/5000 Series

Table of Contents

Related product manuals