No.20S046-00
59/62
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use’s Guide
Name Description
GevIPConfigurationStatus
[GevInterfaceSelector]
Reports the current IP configuration status.
GevPersistentIPAddress
[GevInterfaceSelector]
Controls the Persistent IP address for this logical link.
GevPersistentSubnetMask
[GevInterfaceSelector]
Controls the Persistent subnet mask associated with the Persistent IP
address on this logical link.
GevPersistentDefaultGateway
[GevInterfaceSelector]
Controls the persistent default gateway for this logical link.
GevGVCPExtendedStatusCodesSelector Selects the GigE Vision version to control extended status codes for.
GevGVCPExtendedStatusCodes
[GevGVCPExtendedStatusCodesSelector]
Enables the generation of extended status codes.
GevGVCPPendingAck Enables the generation of PENDING_ACK.
GevPrimaryApplicationSwitchoverKey Controls the key to use to authenticate primary application switchover
requests.
GevGVCPExpendedIDMode Enables the extended IDs mode.
GevCCP Controls the device access privilege of an application.
GevPrimaryApplicationSocket Returns the UDP source port of the primary application.
GevPrimaryApplicationIPAddress Returns the address of the primary application.
GevMCPHostPort Controls the port to which the device must send messages.
GevMCDA Controls the destination IP address for the message channel.
GevMCTT Provides the transmission timeout value in milliseconds.
GevMCRC Controls the number of retransmissions allowed when a message
channel message times out.
GevMCSP This feature indicates the source port for the message channel.
GevStreamChannelSelector Selects the stream channel to control.
GevSCPInterfaceIndex
[GevStreamChannelSelector]
Index of the logical link to use.
GevSCPHostPort
[GevStreamChannelSelector]
Controls the port of the selected channel to which a GVSP transmitter
must send data stream or the port from which a GVSP receiver may
receive data stream.
GeSCPSFireTestPacket
[GevStreamChannelSelector]
Sends a test packet.
GevSCPSDoNotFragment
[GevStreamChannelSelector]
The state of this feature is copied into the "do not fragment" bit of IP
header of each stream packet.
GevSCPSPacketSize
[GevStreamChannelSelector]
This GigE Vision specific feature corresponds to
DeviceStreamChannelPacketSize and should be kept in sync with it.
GevSCPD [GevStreamChannelSelector] Controls the delay (in GEV timestamp counter unit) to insert between
each frame for this stream channel.