EasyManua.ls Logo

Omron H5BR Series - Ratings; Characteristics

Omron H5BR Series
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H5BR
H5BR
3
Ratings
Rated supply voltage
100 to 240 VAC, 50/60 Hz
24 VAC/12 to 24 VDC (permissible ripple: 20% max.)
Operating voltage range
85% to 110% of rated voltage
Power consumption
Approx. 8 VA at 50 Hz, 240 VAC; approx. 5 W at 24 VDC
Reset and control signals
Min. pulse width 1 ms/20ms selectable
Batch count reset and gate
Min. pulse width: Approx. 20 ms
Key protect
Response time: 1 s
One-shot time
0.1 to 99.9 s or hold
Power reset (except A-3, b-1, and F mode)
Min. power opening time: 0.5 s
Signal, reset, gate, batch count reset inputs
No-voltage input
ON impedance: 1 k
"
max. (Approx. 2 mA when 0
"
)
ON residual voltage:2 V max.
OFF impedance: 100 k
"
min.
Key protect input
No-voltage input
ON impedance: 1 k
"
max. (Approx. 2 mA when 0
"
)
ON residual voltage: 1 V max.
OFF impedance: 100 k
"
min.
Control outputs
Contacts: 5 A at 250 VAC, resistance load (cos
#
=1)
Transistor output: Open collector 100mA at 30 VDC max. residual voltage 2 V
max. (Approx. 1 V)
External power supply
80 mA, 12 VDC
$
10% (5% ripple max.)
Ambient temperature
-10
!
Cto55
!
C (with no icing)
Storage temperature
-25
!
Cto65
!
C (with no icing)
Ambient humidity
35% to 85%
Case
Light gray
Characteristics
Repeat accuracy, setting error (including
temperature and voltage effects)
Power start:
$
0.01%
$
0.05 s max.
Control signal start:
$
0.005%
$
0.03 s max. *(rate for set value)
Insulation resistance
100 M
"
min. (at 500 VDC) (between current-carrying terminal and exposed
non-current-carrying metal parts, and between non-continuous contacts)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminal and
exposed non-current-carrying metal parts) for 100 to 240 VAC type
1,000 VAC for 24VAC/12 to 24 VDC type
Impulse withstand voltage
3 kV (between power terminals) for 100 to 240 VAC type, 1 kV for 24 VAC/12 to
24 VDC type
4.5 kV (between current-carrying terminal and exposed non-current-carrying
metal parts) for 100 to 240 VAC type, 1.5 kV for 24 VAC/12 to 24 VDC type
Noise imm unity
$
2 kV (between power terminals) and
$
600 V (between input terminals),
square-wave noise by noise simulator (pulse width: 100 ns/1
%
s, 1-ns rise)
Static immunity
Malfunction: 8 kV; destruction: 15 kV
Vibration Destruction
10 to 55 Hz with 0.75-mm single amplitude each in three directions
Malfunction
10 to 55 Hz with 0.5-mm single amplitude each in three directions
Shock Destruction
294 m/s
2
(30G) each in three directions
Malfunction
98 m/s
2
(10G) each in three directions
Life expectancy Mechanical
10 million operations min.
Electrical
100,000 operations min. (5 A at 250 VAC in load resistance)
Weight
Approx. 270 g (9.6 oz)