EasyManua.ls Logo

Omron H7CC-A Series - H7 CC-R; Precautions on Replacing the AMD-S; Terminal Arrangement and Wiring Connections; Setting Procedure

Omron H7CC-A Series
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H7CC-R@
60
Precautions on Replacing the AMD-S
Terminal Arrangement and Wiring Connections
Note: 1. Wiring must be changed from an 8-pin socket to an 11-pin socket.
2. Take into consideration the length of the wires and the terminal numbers.
3. Order the P2CF-11Connecting Socket separately.
Setting Procedure
Perform the following settings to achieve the functions of the AMD-S
using the H7CC-R11@.
Operation Key Settings
Note: The characters displayed in reverse video are the default
settings.
Characteristics
* When set to AMD mode.
The H7CC-R11 is the recommended model for replacing the AMD-S-series Motion Detector. Refer to the following precautions before
replacing the AMD-S.
AMD-S H7CC-R11@
3456
2187
Sensor
Tc Ta
Relay output
100/110 VAC
(200/220 VAC)
Tb
8PFA
Black (white)
Brown (red)
Blue (black)
Connection Sockets: 8PFA
5
4
678
2
3
11110
9
HOLD HOLD
Tb Ta
Relay output
100 to 240 VAC
Tc
P2CF-11
Black (white)
Brown (red)
Blue
(black)
Sensor
Connection Sockets: P2CF-11
Model
AMD-S
H7CC-R11@
Item Parameters Setting range
Set
value
Measuring
ranges
0.01 to 0.1 s
(AMD-S@1),
0.1 to 1 s
(AMD-S@2),
1 to 10 s
(AMD-S@3)
---
Output
mode
Rotation increase
detection
(AMD-SU@)
---
Rotation decrease
detection
(AMD-SL@)
---
Average
processing
None ---
Input mode Voltage Input ---
Startup
time
Fixed (0.1 to 10 s)
cnts
(CNTS)
10ms
1ms
totm
(TOTM)
Lower
limit
Upper
limit
avgn
(AVGN)
OFF
imod
(IMOD)
PNP
stmr
(STMR)
(99.9s)(0.0s)
0.0
Model
AMD-S H7CC-R11@
Item
Supply voltage
100 to 110 VAC
200 to 220 VAC
100 to 240 VAC
Input method
Voltage input (high: 4 to 14 V,
low: 0 to 1 V)
No-voltage input/voltage
input (high: 4.5 to 30 V,
low: 0 to 2 V)
External power
supply
12 VDC ±1 V, 12 mA
12 VDC (±10%),
100 mA
Relay output 5 A at 200 VAC (resistive load)
3 A at 250 VAC/30 VDC
(resistive load)
Output mode
Rotation increase (AMD-SU@)
Rotation decrease (AMD-SL@)
HI-LO, AREA, HI-HI, LO-
LO
Setting method Input pulse interval (s) Input pulse interval (s) *
Detection
rotation rate
range
6 to 6,000 rpm
(for 1 pulse/rotation)
0.00006 to 20,000 rpm *
(for 1 pulse/rotation)
Startup time
Always from 0.1 to 10 s
(Always 10 s if not specified.)
Setting range: 0.0 to
99.9 s
Life expectancy
Output relay electrical
operations of 500,000 min.
Output relay electrical
operations of 100,000
min.
Memory backup None
Non-volatile memory
(overwrites: 100,000
times min.)

Related product manuals