C-128
Multifunction Preset Counter
H7CX
Dual Counter
Note: 1.
The input mode is increment/decrement mode and the output mode is K-2, D, L, or H.
2.
The dual count calculating mode is subtraction mode and the output mode is K-2, D, L, or H.
Function Setting Mode
Note: 1.
The setting range varies with the output mode.
2.
The setting range varies with the model and the input mode.
3.
HOLD cannot be set when the output mode is K-2.
Parameter name Parameter Setting range Default value Unit Set value
Dual count
value, dual count
set value
Dual count value --- -99999 to 999999
(
-999 to 9999) 0 --- ---
Dual count set
value
--- 0 to 999999
(
0 to 9999) (For conditions other
than those described in note 2.)
0 ---
-99999 to 999999
(
-999 to 9999)
(See note 2.)
CP1 present
value, CP2
present value
CP1 present
value
--- 0 to 999999
(
0 to 9999) 0 --- ---
CP2 present
value
--- 0 to 999999
(
0 to 9999) 0 --- ---
Parameter name Parameter Setting range Default value Unit Set value
Input mode cntm up/down/ud-a/ud-b/ud-c (See note 1.) up ---
Dual count calculating
mode
caln add/sub (See note 1.) add ---
Output mode outm n/f/c/r/k-1/p/q/a/k-2/d/l/h (See note 2.) n ---
One-shot output time otim 0.01 to 99.99 0.50 s
One-shot output 2 time otm2 0.01 to 99.99 0.50 s
One-shot output 1 time otm1 hold/0.01 to 99.99 (See note 3.) hold s
Counting speed cnts 30h=/skh= 30h= ---
Reset input signal width iflt 20ms/1ms 20ms ---
Decimal point position dp ------/-----.-/----.--/---.---
(----/---.-/--.--/-.---)
------
(----)
Prescale value pscl 0.001 to 99.999 (0.001 to 9.999) 1.000 ---
NPN/PNP input mode imod npn/pnp npn ---
Display color colr red/grn/r-g/g-r red ---
Output allocation otst off/on off ---
Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 kp-1 ---