Multifunction Preset Counter
H7CX
C-127
Counters
Lists of Settings
Fill in your set values in the set value column of the following tables and utilize the tables for quick reference.
Configuration Selection Mode
Note: 1.
The setting range varies with the model.
2.
The default value for H7CX-AW
@
/-A4W
@
models is 2cnt.
Settings for Counter Operation
Run Mode
1-stage Counter
2-stage Counter
Total and Preset Counter
Batch Counter
Parameter
name
Parameter Setting range Default value Unit Set value
Configuration
selection
func 1cnt/2cnt/tcnt/bcnt/dcnt/taco (See note 1.) 1cnt
(See note 2.)
---
DIP switch
monitor
dip on/off off --- ---
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value
Present value --- -99999 to 999999
(
-999 to 9999) 0 -- ---
Set value --- 0 to 999999
(
0 to 9999) (For conditions other
than those described in note 1.)
0 ---
-99999 to 999999
(
-999 to 9999)
(See note 1.)
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value 1
Present value --- -99999 to 999999
(
-999 to 9999) 0 --- ---
Set value 1 --- 0 to 999999
(
0 to 9999) (For conditions other
than those described in note 1.)
0 ---
-99999 to 999999
(
-999 to 9999)
(See note 1.)
0
Present value,
set value 2
Present value --- -99999 to 999999
(
-999 to 9999) 0 --- ---
Set value 2 --- 0 to 999999
(
0 to 9999) (For conditions other
than those described in note 1.)
0 ---
-99999 to 999999
(
-999 to 9999)
(See note 1.)
0
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value
Present value --- -99999 to 999999
(
-999 to 9999) 0 --- ---
Set value --- 0 to 999999
(
0 to 9999) (For conditions other
than those described in note 1.)
0 ---
-99999 to 999999
(
-999 to 9999)
(See note 1.)
Total count value --- -99999 to 999999
(
-999 to 9999) 0 --- ---
Parameter name Parameter Setting range Default value Unit Set value
Present value,
set value
Present value --- -99999 to 999999
(
-999 to 9999) 0 --- ---
Set value --- 0 to 999999
(
0 to 9999) (For conditions other
than those described in note 1.)
0 ---
-99999 to 999999
(
-999 to 9999)
(See note 1.)
Batch count
value, batch
count set value
Batch count
value
--- 0 to 999999
(
0 to 9999) 0 --- ---
Batch count
set value
--- 0 to 999999
(
0 to 9999) 0 ---