Preset Counter/Timer
H8GN
C-65
Counters
I/O Functions
Terminal Arrangement
Note:
(2) and (6) are connected internally.
Do not use unused terminals as relay terminals.
Wiring
Use the following type of crimp terminals for M3 screw.
Inputs Counter inputs CP1/CP2
Receive count signals.
Receive increment, decrement, individual, and quadrature inputs.
In increment mode and decrement mode, CP1 is used for the count input and CP2 is used
for count prohibit input.
Reset
Resets the present value. (Totalizing count value is not reset.)
(In increment mode or increment/decrement mode, the present value returns to 0; in Decre-
ment Mode the present value returns to the set value.)
The count input is not received during resetting.
The RST indicator is lit during resetting.
Timer inputs Start
Starts timing.
Reset
Resets the timer. (In elapsed time mode the time returns to 0; in remaining time mode, the
time returns to the set value.)
During resetting, timing stops and the control output turns OFF.
The RST indicator is lit during resetting.
Gate
Prohibits timing operation.
Outputs OUT
Output made according to the output mode setting when the set value is reached.
RS-485
Communications*
Contact inputs
Output
Open-collector inputs
*Only models with communications
Reset
Not
connected
CP1/
Start
CP2/
Gate
24-VDC
power supply
5.8 mm max.
5.8 mm max.