Preset Counter/Timer
H8GN
C-85
Counters
Adjustment Level
Initial Setting Level
Communications Setting Level
Parameter name Parameter Setting range Default
value
Unit Set value
Communications writing
control
cmwt on/off off
SV 0 sp-0 Same as for PV in the above PV/SV column.
SV 1 sp-1 Same as for PV in the above PV/SV column.
SV 2 sp-2 Same as for PV in the above PV/SV column.
SV 3 sp-3 Same as for PV in the above PV/SV column.
Cycle time Timer (Out-
put mode=Z)
cyti 0.000 to 9.999 (Time range=-.---s) 0.000 Second
0.00 to 99.99 (Time range=--.--s) 0.00 Second
0.0 to 999.9 (Time range=---.-s) 0.0 Second
0 to 9999 (Time range=----s) 0 Second
0:00 to 99:59 (Time range=--min--s) 0:00 Minute: Sec-
ond
0.0 to 999.9 (Time range=---.-min) 0.0 Minute
0:00 to 99:59 (Time range=--h--min) 0:00 Hour: Minute
0.0 to 999.9 (Time range=---.-h) 0.0 Hour
0 to 9999 (Time range=----h) 0 Hour
Parameter name Parameter Setting range Default
value
Unit Set value
Counter/Timer selection func cnt/tim cnt
Input mode cntm up/down/ud-b/ud-c up
Time range timr -.---s/--.--s/---.-s/----s/
--min--s/---.-min/--h--min/
---.-h ----h
--.-- Second
Timer mode timm up/down up
Output mode for counter
function
outm n/f/c/kn
Output mode for timer func-
tion
outm a/b/d/e/f/=a
Output time Counter otim 0.01 to 99.99 0.50 Second
Timer 0.00 to 99.99 0.00 Second
Counting speed cnts 30h=/skh= 30h=
Input signal width iflt 20ms/1ms 20ms
Decimal point position dp ----/---.-/--.--/-.--- ----
Prescale value pscl 0.001 to 9.999 1.000
Input signal edge edge up/down up
Move to function setting lev-
el
amou -999 to 9999 0
Parameter name Parameter Setting range Default
value
Unit Set value
Communications unit num-
ber
u-no 0 to 99 1
Baud rate bps 1.2/2.4/4.8/9.6 9.6 kbps
Communications data
length
len 7/87bit
Stop bits sbit 1/22bit
Parity prty none/eUen/odd eUen