H8CA-S Solid-State Counter/Timer
1/16 DIN, Easy-to-Operate
Combination Counter and Timer
Operation selectable as preset counter
or timer
6-digit LCD display—
Present Value: 8 mm (0.32 in)
Set Value: 4 mm (0.16 in)
Nonsignificant zeros suppressible from
preset or count value display
Selectable power supply voltages
24 to 240 VAC and 12 to 120 VDC
Memory protection
4 programmable output modes available for
both counter and timer functions
Ordering Information
Counter/Timer
Note:
Do not use the contact input at a counting speed of 1 kcps.
Mounting style Surface/flush mounting
Operating function Preset counter/timer (selectable)
Operating system (mode) Counter: reversible (Three input modes and four operating modes are selectable)
Timer: time-limit operation, integrating operation (Four operating modes are
selectable)
Backup power supply for memory protection Provided: Approx. 10 years at 20° C (68° F)
Number of counts 0 to 999999 (6 digits)
Timing ranges 0.00 to 9999.99 s, 0.0 to 99999.9 min., 0.0 to 99999.9 h (6 digits)
External connection Socket
Display type 6-digit backlit LCD; 8 mm (0.32 in) Present Value, 4 mm (0.16 in) Set Value
Count and reset input for counter function;
reset and gate input for timer function
No-voltage input (See Note.)
(solid-state/contact input)
Voltage input
Control output Contact Solid-state Contact Solid-state
Power supply/
counting speed
AC 30 cps
H8CA-SAL H8CA-SALS H8CA-SALV H8CA-SALVS
1 kcps
H8CA-SAH H8CA-SAHS H8CA-SAHV H8CA-SAHVS
DC 30 cps
H8CA-SDL H8CA-SDLS H8CA-SDLV H8CA-SDLVS
1 kcps
H8CA-SDH H8CA-SDHS H8CA-SDHV H8CA-SDHVS
Question and Answer IconNeed help?

Do you have a question about the Omron H8CA-S and is the answer not in the manual?

Summary

Ordering Information

Counter;Timer Specifications

Details product specifications and available models for the Counter/Timer series.

Accessories

Accessory List and Part Numbers

Lists available accessories for the H8CA-S, including descriptions and part numbers.

Specifications

Ratings and Performance

Covers voltage, power consumption, counting speed, and other key ratings.

Characteristics

Timer Mode Performance

Details accuracy, error margins, and environmental effects for timer functions.

Engineering Data

Electrical Service Life

Provides charts illustrating electrical service life under resistive and inductive loads.

Timing Charts

Counter and Timer Operation Timing

Illustrates timing sequences for counter and timer functions.

Count Output Modes

Output Mode Input Diagrams

Shows input timing diagrams for different count output modes.

Input Signal Functions

Signal Input Type and Modes

Explains different input signal types and their functions in counter/timer modes.

Output Modes

Counter;Timer Output Behavior

Describes the behavior of output modes N, F, C, and R during operation.

Dimensions

Unit and Panel Dimensions

Provides detailed dimensions for the H8CA-S unit and panel cutout requirements.

Accessories

Mounting Accessory Details

Details specific mounting accessories like sockets and adapters with dimensions.

Mounting Accessories

Panel Adapter and Mounting Tracks

Describes the Y92F-30 panel mounting adapter and various mounting tracks.

Nomenclature

Key and Display Identification

Identifies the function of each key and display element on the H8CA-S unit.

Programming

Selecting Function Mode

Guides on how to select the counter/timer function, input, and output modes.

Programming

Setting Examples

Provides step-by-step examples for setting counter and timer functions.

Programming

Presetting Numeric Values

Explains the procedure for presetting count or timer values.

Connections

Terminal Arrangements and Power Supply

Shows terminal layout and how to connect the power supply for the unit.

Control Output Connections

Load Circuit and Delay Time

Details connecting the load circuit and output delay times for different outputs.

Reset Input Connections

Input Types and Wiring

Illustrates connections for various reset input types like NPN, PNP, and voltage inputs.

Count Input Connections

No-Voltage and Voltage Inputs

Shows how to connect no-voltage and voltage input signals for counting.

Operations

Power Failure Detection and Display

Explains the unit's power failure detection and operational display indicators.

Mounting

Surface and Panel Mounting

Covers methods for surface mounting and flush panel mounting of the unit.

Mounting

Multi-Unit Arrangement and Removal

Details arranging multiple units and the procedure for removing the unit from a panel.

Overview

The Omron H8CA-S is a versatile 1/16 DIN solid-state counter/timer designed for ease of operation, offering a combination of counting and timing functionalities in a single unit. This device is highly adaptable, allowing users to select between preset counter or timer operation modes, making it suitable for a wide range of industrial applications.

Function Description

The H8CA-S features a clear 6-digit LCD display, with a present value display of 8 mm (0.32 in) and a set value display of 4 mm (0.16 in). A convenient feature of this display is the suppression of non-significant zeros from both the preset and count value displays, enhancing readability. The device supports a broad range of power supply voltages, from 24 to 240 VAC and 12 to 120 VDC, ensuring compatibility with various power systems. For data integrity, it includes memory protection, safeguarding settings and count values even during power interruptions.

For counter functions, the H8CA-S is reversible, offering three input modes and four operating modes to accommodate diverse counting requirements. In timer mode, it supports time-limit operation and integrating operation, also with four selectable operating modes, providing flexibility for different timing scenarios. The device offers four programmable output modes for both counter and timer functions, allowing for customized control logic.

The H8CA-S is designed for surface or flush mounting, providing installation flexibility. Its operating function is selectable between preset counter and timer. The operating system (mode) for the counter includes reversible counting with three input modes and four operating modes, while the timer offers time-limit and integrating operations with four operating modes.

Memory protection is provided by a backup power supply, ensuring data retention for approximately 10 years at 20°C (68°F). The device can count up to 999,999 (6 digits) and offers extensive timing ranges: 0.00 to 9999.99 seconds, 0.0 to 99999.9 minutes, and 0.0 to 99999.9 hours (6 digits). External connection is facilitated via a socket. The display is a 6-digit backlit LCD, showing an 8 mm (0.32 in) present value and a 4 mm (0.16 in) set value.

Input signals for counter functions include count and reset inputs, while for timer functions, start and gate inputs are used. These inputs can be no-voltage (solid-state/contact input) or voltage input. The control output can be either contact or solid-state, depending on the model.

Usage Features

The H8CA-S offers intuitive programming for selecting function modes. To select between timer or counter functions, terminals 1 and 3 must be connected. The device is shipped in counter function, input mode "A," output mode "N," and preset value 1. The "MODE" indicator lights up on the display, and "COUNTS" will blink when the setting key is pressed, allowing the user to navigate to the desired function. Once the function is selected, "COUNTS" will stop blinking, and one of the input modes will begin blinking. The user can then select the desired input mode (e.g., "A") and output mode (e.g., "N"). After setting, terminals 1 and 3 should be disconnected.

Presetting numeric values is straightforward and can be done whether the power supply is ON or OFF. The user can set the desired value by pressing the setting key and incrementing values using the "+" key. Unnecessary higher digits can be preset to 0. If the set value is 0 and the displayed count is also 0, the output will go ON; in this case, pressing reset after presetting will turn the output OFF.

The device's input signals support various configurations. For no-voltage input, the counter output signal is high when the contact turns ON or the open collector transistor is in the ON state, and low when the contact turns OFF or the transistor is in the OFF state. For voltage input, a signal voltage level of 5 to 30 V is considered high, and 0 to 2 V is considered low.

The H8CA-S supports different counter modes:

  • Counter mode A (command input): The count value increases when count input 2 (CP2) voltage goes low and decreases when CP2 voltage goes up. This mode also supports addition/subtraction control.
  • Counter mode B (individual input): This mode uses separate inputs for addition and subtraction counting.
  • Counter mode C (phase difference): The count value increases when the phase of count input 2 (CP2) is delayed with respect to count input 1 (CP1), and decreases when CP2 is ahead of CP1.
  • Timer operation: This uses start and gate inputs.

Output modes include:

  • Output Mode N: Present value display and outputs are maintained until reset.
  • Output Mode F: Present value runs continuously, and outputs are maintained until reset.
  • Output Mode C: Present value is reset when the preset count is reached. Outputs are one-shot, fixed at 0.5 seconds, and operate repeatedly.
  • Output Mode R: Present value display returns to reset start status after expiration of a one-shot time period. Outputs are one-shot, fixed at 0.5 seconds, and operate repeatedly.

Maintenance Features

The H8CA-S includes power failure detection, indicated by a flickering "PW OFF" display, which alerts users when the control power supply is off. This feature helps in diagnosing power-related issues. The device's memory protection, with a 10-year backup power supply, minimizes data loss during power outages, reducing the need for frequent reprogramming.

For connections, the device provides clear terminal arrangements for power supply, reset input, count input, and control output. When connecting the power supply, it is important to pay attention to polarity for DC-operated models. For external signal input contacts and transistors, it is recommended to use a power supply with an isolated transformer to prevent current feedback and short-circuiting.

When mounting multiple H8CA-S units, specific guidelines are provided to ensure proper engagement and disengagement of hooks, preventing damage and facilitating maintenance. For panel mounting, the Y92F-30 adapter allows for flush mounting, and instructions are given for secure installation and removal.

The H8CA-S has a built-in lithium battery for memory protection. Proper disposal of the old battery is crucial, as lithium batteries can explode if incinerated. This highlights the importance of following environmental guidelines for device maintenance.

Overall, the Omron H8CA-S is a robust and user-friendly device, offering comprehensive counting and timing functionalities with features designed for reliability, ease of use, and straightforward maintenance in industrial environments.

Omron H8CA-S Specifications

General IconGeneral
Number of Pins8
Contact Rating5 A at 250 VAC
OutputRelay
Operating Temperature-10°C to 55°C
Storage Temperature-25°C to 65°C