BEFORE TAKING A MEASUREMENT
5
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for
30 minutes before taking a measurement. Rest for at least 15 minutes
before taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during
stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your left arm.
5. Sit in a chair with your feet flat on the floor. Rest your left arm on a
table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your
physician. A single measurement does not provide an accurate
indication of your true blood pressure. You need to take and record
several readings over a period of time. Try to measure your blood
pressure at the same time each day for consistency.
8. Wait 2-3 minutes between measurements. The wait time allows the
arteries to return to the condition prior to taking the blood pressure
measurement. You may need to increase the wait time depending on
your individual physiological characteristics.
FINAL.HEM-432CN2-IM 2/23/10 10:56 AM Page 5

Other manuals for Omron HEM-432C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron HEM-432C and is the answer not in the manual?

Omron HEM-432C Specifications

Measurement Specifications IconMeasurement Specifications
pressure measurement range0 - 280 mmHg
pulse measurement range40 - 200/minute
pressure accuracy±3 mmHg or 2 % of reading
pulse accuracy±5% of reading
Operating Environment IconOperating Environment
operating temperature50°F to 104°F (10°C to 40°C)
operating humidity30 to 85% RH maximum
storage temperature-4°F to 140°F (-20°C to 60°C)
storage humidity10 to 95% RH maximum
Power IconPower
power source4 “AAA” batteries
battery usageApprox. 300 usages
Weight and Dimensions IconWeight and Dimensions
unit weight1.0 lbs
unit dimensions5.13" x 3.5" x 6.88"
master weight14.25 lbs
master dimensions22" x 11" x 8.25"
monitor weightApproximately 8 oz (225 g)
cuff sizeApproximately 5 1/2" x 18 7/8" (140 mm x 480 mm)
cuff circumference9" to 13" (229 mm x 330 mm)