8-56
8-6 Extended Parameters
OMNUC G5-SERIES AC SERVOMOTOR AND SERVO DRIVE USER'S MANUAL
   8
Parameter Details
Explanation of Set Values
 Select the method to set the forward and reverse torque limits.
If this parameter is set to 1, the forward and reverse torque limit input will be limited by the No. 1
Torque Limit (Pn013).
When using torque control, the No. 1 Torque Limit (Pn013) will be the limit value for forward and
reverse operation regardless of the setting of this parameter.
 Set the limit value for the output torque (Pn013: No. 1 Torque Limit, Pn522: No. 2 Torque Limit) of
the motor. 
Refer to information on the Torque Limit Selection (Pn521) to select the torque limits.
During torque control, maximum torques for both forward and reverse directions are limited.
Settings in Torque Limit Selection (Pn521) and No. 2 Torque Limit (Pn522) will be ignored.
Make the settings as a percentage of the rated torque. [Example] Maximum torque is limited to 150%
Refer to "5-3 Torque Control" (P.5-14) for more information on torque limits and the torque limit selection.
Pn521
Torque Limit Selection
Setting 
range
0 to 6 Unit −
Default 
setting
1
Power OFF 
and ON
−
Position
Speed
Fully-closed
Torque 
Limit 
Selection
(Pn521)
Torque 
limit 
switching 
input 
(TLSEL)
Torque Limit 
Switching 
Setting (Pn523 
and 524)
Forward 
torque limit 
input (PCL)
Reverse 
torque limit 
input (NCL)
Forward 
direction 
torque 
limit
Reverse 
direction 
torque 
limit
0 0 to 10 V -10 to 0 V PCL NCL 
1 −− Pn013
2 −− Pn013 Pn522
3
OFF Enabled Pn013
ON Enabled Pn522
4 0 to 10 V 0 to 10 V PCL  NCL 
5 0 to 10 V Not affected PCL  PCL 
6
OFF − Pn013 Pn522
ON − Pn525 Pn526
Pn522
No. 2 Torque Limit
Setting 
range
0 to 500 Unit %
Default 
setting
500
Power OFF 
and ON
−
Position
Speed
Fully-closed
Speed
200
100 (rated)
(rated)100
200
300
Torque [%]
300 (maximum)
(maximum)
Reverse
Forward
When Pn013 or Pn522 = 150