NO: SD-076 PRODUCT: S8VS Power Supplies
DATE: July 2013 TYPE: Partial Discontinuation
Selected S8VS Switch Mode Power Supplies will be
Discontinued June 2014; Use S8VS or S8VK Models
Effective Date: Last orders due June, 2014
Affected Parts
Product discontinuation Recommended replacement
S8VS-01505 S8VK-G01505
S8VS-01512 S8VK-G01512
S8VS-01524 S8VK-G01524
S8VS-03005 S8VK-G03005
S8VS-03012 S8VK-G03012
S8VS-03024 S8VK-G03024
S8VS-06024 S8VS-06024A
S8VK-C06024
S8VK-G06024
S8VS-06024-F S8VS-06024A-F
S8VS-9024 S8VS-09024A
S8VK-G12024
S8VS-09024-F S8VS-09024A-F
S8VS-12024 S8VS-12024A
S8VK-C12024
S8VK-G12024
S8VS-12024-F S8VS-12024A-F
S8VS-18024 S8VS-18024A
Compare features and specifications on the following pages.
Reference Documentation
Description Media Publication number
S8VS Data Sheet PDF
T026-E1-08
S8VK-G Data Sheet PDF
T056-E1-01

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Omron S8VS-12024 and is the answer not in the manual?

Omron S8VS-12024 Specifications

General IconGeneral
Output Voltage24 VDC
Output Current5 A
Output Power120 W
Input Voltage85-264 VAC, 120-370 VDC
Operating Temperature-10 to 60 °C
Protection FeaturesOvervoltage
Cooling MethodConvection

Summary

Action Alert! S8 VS Discontinuation

Affected Parts and Replacements

Lists S8VS models being discontinued and their S8VK replacements.

Wiring Diagram

Specifications

S8 VS vs. S8 VK Specifications Comparison

Compares technical specifications, including input, output, and environmental ratings.

S8 VK-G Product Introduction

S8 VK-G Features and Benefits

Highlights key features of the S8VK-G power supply, focusing on operation and installation.

S8 VK-G Detailed Specifications

S8 VK-G Input, Output, and Functions

Details electrical ratings, characteristics, and additional functions of the S8VK-G series.

S8 VS Engineering Data

S8 VS Derating Curves

Presents derating curves for S8VS power supplies based on ambient temperature.

S8 VS Operation and Protection

S8 VS Mounting and Overload Protection

Covers mounting methods, overload protection, and peak current limits for S8VS power supplies.

S8 VS Operational Safeguards

S8 VS Overvoltage and Undervoltage Alarms

Explains overvoltage protection and undervoltage alarm functions for S8VS power supplies.

S8 VS Safety and Operation

S8 VS Wiring and Environment

S8 VS Maintenance Monitoring

S8 VS Series Overview

S8 VS Detailed Specifications

S8 VS Mounting and Protection

S8 VS Display and Alarm Functions

S8 VS Self-Diagnostics

S8 VS Safety and Wiring