EasyManua.ls Logo

Omron S8VS Series

Omron S8VS Series
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
New Product
Switch Mode Power Supply
S8VS
(15/30/60/90/120/180/240/480-W Models)
60/90/120/180/240/480-W Models
New Models with Indication
Monitor and Simple Functions
for Easy System
Commissioning
New 90-W models with indication monitor that
conform to UL Class 2 Output standards.
New models with screwless terminal blocks
and indication monitor.
• Status displayed on 3-digit, 7-segment display.
Safety standards:
UL508/60950-1,
CSA C22.2 No. 14/60950-1
(15-W and 30-W models),
CSA C22.2 No. 107.1/60950-1
(60-W to 240-W and 480-W models),
EN 50178 (= VDE0160)
Input conditions: DC input is also possible from 80 to 370 VDC (BE models only, not compliant with EC Directives
and other safety standards).
15/30-W Models
Compact, Thin Power Supplies
That Mount Just About Anywhere
to Contribute to Control Panel
Downsizing
• Compact and thin: 22.5 × 85 × 96.5 mm (W × H × D).
Three mounting directions
(standard, horizontal, facing horizontal).
Mounting directly to the panel is possible.
Safety standards:
UL508/60950-1/1604, cUL: CSA C22.2 No. 14/60950-1/213,
EN50178 (= VDE0160).
Features Common to All Models
Mount to DIN Rail.
Complies with SEMI F47-0706 (200-VAC input).
RoHS-compliant.
!
Refer to Safety Precautions for All Power Supplies and Safety
Precautions on page 31.
1
Question and Answer IconNeed help?

Do you have a question about the Omron S8VS Series and is the answer not in the manual?

Omron S8VS Series Specifications

General IconGeneral
Output Power60 W, 120 W, 240 W
MountingDIN Rail Mounting
ProtectionOvercurrent protection, Overvoltage protection
Safety StandardsUL508, EN50178
Dimensions22.5 x 90 x 100 mm
Output Voltage24 VDC

Summary

Switch Mode Power Supply S8 VS Overview

New Models with Indication Monitor

Highlights new S8VS models with status indication and simple functions for easy system commissioning.

1530-W Models Overview

Details compact and thin power supplies designed for control panel downsizing.

Common Features

Lists features applicable to all S8VS power supply models.

Model Number Structure

Model Number Legend

Explains the coding system used to define S8VS power supply model numbers.

Ordering Information

Models without Indication Monitor

Lists standard S8VS models without status indication monitors.

Models with Indication Monitor (Maintenance Forecast)

Lists S8VS models with maintenance forecast monitor functionality.

Models with Indication Monitor (Total Run Time)

Lists S8VS models with total run time monitor functionality.

Specifications (15-W, 30-W Models)

Ratings and Characteristics

Details electrical and environmental ratings for 15-W and 30-W S8VS power supplies.

Specifications (60-W, 90-W Models)

Additional Functions

Details advanced functions like output indications and monitor outputs for 60-W and 90-W models.

Other Specifications

Covers EMI, EMS, approved standards, and weight for 60-W and 90-W models.

Specifications (120-W, 180-W Models)

Additional Functions

Details advanced functions like output indications and monitor outputs for 120-W and 180-W models.

Other Specifications

Covers EMI, EMS, approved standards, and weight for 120-W and 180-W models.

Specifications (240-W, 480-W Models)

Additional Functions

Details advanced functions like output indications and monitor outputs for 240-W and 480-W models.

Other Specifications

Covers EMI, EMS, approved standards, and weight for 240-W and 480-W models.

Connections and Block Diagrams

Block Diagrams (15-W to 60-W Models)

Illustrates internal circuit diagrams for 15-W, 30-W, and 60-W S8VS power supply models.

Block Diagrams (60-W, 90-W Models)

SinkingSourcingNo Alarm Types

Shows block diagrams for 60-W and 90-W S8VS models, detailing alarm output configurations.

Block Diagrams (90-W, 120-W Models)

SinkingSourcingNo Alarm Types

Illustrates block diagrams for 90-W and 120-W S8VS models with various alarm output options.

Block Diagrams (120-W, 180-W Models)

SinkingSourcingNo Alarm Types

Presents block diagrams for 120-W and 180-W S8VS models, showing circuit configurations.

Block Diagrams (180-W, 240-W Models)

SinkingSourcingNo Alarm Types

Details block diagrams for 180-W and 240-W S8VS models, including alarm output variations.

Block Diagrams (240-W, 480-W Models)

SinkingSourcing Types

Shows block diagrams for 240-W and 480-W S8VS models, illustrating sinking and sourcing configurations.

Construction and Nomenclature (15-W, 30-W Models)

Nomenclature Details

Provides a detailed breakdown of the parts and terminals for 15-W and 30-W S8VS models.

Engineering Data (Derating Curves)

Presents derating curves showing load capacity versus ambient temperature for 15-W and 30-W models.

Mounting and Protection Features

Mounting Methods

Explains various mounting orientations and considerations for S8VS power supplies.

Overvoltage and Overload Protection

Describes the built-in overvoltage and overload protection mechanisms for safety.

Timing and Undervoltage Alarm

Details inrush current, startup time, hold time, and undervoltage alarm indication.

Construction and Nomenclature (60-W to 240-W Models)

Nomenclature Details

Explains the parts and terminal identification for 60-W to 240-W S8VS models.

Construction and Nomenclature (480-W Models)

Nomenclature Details

Details the parts and terminal identification for the 480-W S8VS models.

Mode Change and Operation Modes

Operation Mode Display

Describes the various states and indications in the S8VS power supply's operation mode.

Setting Mode Functions

Explains how to access and use the setting mode for parameter configuration.

Status Monitoring and Alarms

Peak Hold Reset and Multiple Alarms

Covers resetting peak hold current and handling multiple simultaneous alarms.

Undervoltage Alarm Details

Explains the indication and output behavior for undervoltage conditions.

Self-Diagnostics Function

Error Code Descriptions

Lists and explains error codes, output status, and restoration methods for self-diagnostics.

Maintenance Forecast Monitor

Display and Indication Details

Describes how the maintenance forecast monitor displays status and indications.

Forecast Function Logic

Explains the logic behind the maintenance forecast, including deterioration and alarm triggers.

Maintenance Forecast Insights

Indicated Values vs. Output Logic

Details the relationship between displayed values and output signals for maintenance forecasts.

Reliability and Life Expectancy

Provides reference values for MTBF and life expectancy of the power supply.

Total Run Time Monitor Function

Accumulated Time Display and Alarms

Explains the display of accumulated operating time and alarm triggers for the total run time monitor.

Engineering Data and Performance

Derating Curves and Peak Current

Presents derating curves and peak current limitations for various models.

Protection Features and Timing

Details overvoltage protection, overload protection, and timing characteristics.

Undervoltage Alarm Functionality

Alarm Indication and Output Logic

Describes the function of the undervoltage alarm, including its indication and output.

Dimensions (Screw Terminal Models)

15-W to 180-W Models

Shows physical dimensions and mounting details for 15-W to 180-W S8VS models with screw terminals.

Dimensions (240-W, 480-W, and Screwless Models)

240-W and 480-W Models

Provides dimensions and mounting details for 240-W and 480-W S8VS models.

Screwless Terminal Models

Shows dimensions for S8VS models equipped with screwless terminal blocks.

Dimensions (Screwless Terminal Models)

180-W to 480-W Models

Presents physical dimensions for 180-W to 480-W S8VS models with screwless terminal blocks.

DIN Rail Mounting Accessories

Mounting Rails and End Plates

Details the specifications for aluminum mounting rails and PFP-M end plates.

Mounting Brackets

Bracket Types and Specifications

Lists available mounting brackets, their models, dimensions, and appearance.

Safety Precautions

Wiring Guidelines

Provides essential safety guidelines for wiring S8VS power supplies correctly.

Recommended Wire Types

Specifies suitable wire types and sizes for connecting to S8VS power supplies.

Usage and Environmental Considerations

Installation and Operating Environment

Discusses suitable installation locations, operating life factors, and ambient conditions.

Maintenance and Periodic Checks

Outlines periodic checks for indication monitor functions and storage guidelines.

Safety and Protection Features

Overcurrent and Alarm Outputs

Covers overcurrent protection, alarm output specifications, and dielectric strength testing.

Dielectric Strength and Inrush Current

Details dielectric strength testing considerations and inrush current effects.

Product Adjustments and Operation Scenarios

Voltage Adjustment and Mounting

Explains output voltage adjustment, DIN rail mounting, and series operation.

Operational Scenarios

Covers troubleshooting for no output voltage and buzzing noise during startup.

Catalog Information and Disclaimers

Warranty and Liability

Outlines OMRON's product warranty terms and limitations of liability.

Application Suitability

Emphasizes user responsibility for determining product suitability for specific applications.

Disclaimers and Specifications

Notes on specification changes, dimensions, weights, and performance data.