F3SJ-B-02TS
Quick Installation Manual
Depending on the unit's model and settings of floating blanking function, detection capability may vary.
Use a test rod with an appropriate diameter for inspection. The model name of test rod is as follows.
The sensor can detect a test rod wherever it is in the detection zone. In other words, when a test rod is
inserted into the detection zone, the stable-state indicators (STB) turn off and the ON/OFF output-state
indicators turn red.
When the external test function is used:
ON/OFF-state indicators turn red when the test input line is short-circuited to Vs-3V to Vs.
When the external device monitoring function is used:
When the F3SJ-B-02TS is blocked and the external device monitoring input terminal is open, it enters a
lockout state.
When using muting lamp:
Under muting state, a signal that indicates muting state is output to the auxiliary output.
Under override state, a signal that indicates override state is output to the auxiliary output.
-Checking that Hazardous Parts Stop While the Machine Operates
The hazardous parts stop immediately when a test rod is inserted into the detection zone at three posi-
tions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter and
receiver". (Use the appropriate test rod.)
The hazardous parts remain stopped as long as the test rod is in the detection zone.
The hazardous parts stop when the power of the F3SJ-B-02TS is turned OFF.
The actual response time of the whole machine is equal to or less than the calculated value.
Maintenance Checklists
To ensure safety, keep a record of the inspection results. When the user is a different person from those who
installed or designed the system, he/she must be properly trained for maintenance.
Checklists
-Inspection at Startup and When Changing Operators
There is no approach route other than through the detection zone of the F3SJ-B-02TS.
Part of the operator's body always remains in the detection zone of the F3SJ-B-02TS when working
around the machine's hazardous part.
The actual safety distance is equal to or greater than the calculated value.
There must be no dirt on or damage to the optical surface of the F3SJ-B-02TS.
ON/OFF-state indicators turn red when the test input line is short-circuited to Vs-3V to Vs.
When muting lamp is used, a muting lamp must be clear and free of dirt or degradation.
The test rod is not deformed.
When the power of the F3SJ-B-02TS is turned ON while nothing is in the detection zone, it must operate
as follows:
The power indicator and ON/OFF-state indicators turn green within 2 seconds after the F3SJ-B-02TS is
turned ON.
Nothing should exist in the detection zone and stable-state indicators must turn ON at power on.
The test rod is detected when it is moved around in the detection zone as shown in the diagram of Pre-
Operation Checklists. In other words, when a test rod is inserted into the detection zone, the stable-state
indicators (STB) turn off and the ON/OFF-state indicators turn red.
When muting function is used, installation condition of muting sensor must not be changed.
Model name Diameter
F39-TRD25 Dia. 25mm
Start
Stop
Mounting/Beam Alignment
Wiring
Function Selection
Pre-Operation Checklist /
Maintenance Checklists