Appendices
A - 30
NX-series Communications Interface Units User’s Manual (W540)
The following Unit operation settings are made for the CIF Unit from the Support Software. Refer to
Section 6 Unit Settings for the meanings of the settings and the setting procedures.
The following divided data sizes are set from the Support Software as the default values. Refer to 6-3
Setting the Divided Data Size
on
page 6-6 for a detailed setting procedure.
Unit Operation Settings for the CIF Unit
Item Setting
Baud Rate [bps] 9,600
Data Bit Length [bits] 7
Parity Even
Stop Bits [bits] 2
Initial RS Signal Value On
Flow Control None
Flow Control Target Send/receive
Number of Characters to Determine the End 35
Transmission Buffering Enable/Disable Setting Enabled
Event Level Settings All events set to observations.
Setting the Divided Data Size
Data I/O entry name Size [bytes]
Input data Ch1 Input Data 01 to 05 20
Output data Ch1 Output Data 01 to 05 20