EasyManuals Logo

Omron V7 User Manual

Omron V7
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
Varispeed V7
5
Frequenc
IP 20 type 0.1 to 4 Kw
IP20 / NEMA1 type 5.5/7.5 Kw
Dimensions
Voltage class
Max. applicable
motor output kW
Inverter model
CIMR V7AZ
Figure
Dimensions in mm
Weight kg
Cooling
method
W H D W1 H1 H2 D1
Three-phase
200 V
0.12 20P1
1 68
128
76
56
118
5
10
0.6
Self cooled0.25 20P2 0.6
0.55 20P4 108 42 0.9
1.1 20P7 128 62 1.1
Fan cooled
1.5 21P5
2
108
131
96
5
64
1.4
2.2 22P2 140 1.5
4.0 24P0 140 143 128 71 2.1
Single-phase
200 V
0.12 B0P1
1 68
128
76
56 118 5
10
0.6
Self cooled0.25 B0P2 76 0.7
0.55 B0P4 131 42 1.0
1.1 B0P7
2
108
140 96
118 5
64
1.5
Fan cooled
1.5 B1P5 156 96 1.5
2.2 B2P2 140 163 128
71
2.2
4.0 B4P0 170 180 158 2.9
Three-phase
400 V
0.37 40P2
2
108
128
92
96
118 5
16 1.0
Self cooled0.55 40P4 110 34 1.1
1.1 40P7 140
64
1.5
1.5 41P5
156
1.5
Fan cooled
2.2 42P2 1.5
3.0 43P0
140 143 128 71
2.1
4.0 44P0 2.1
Voltage class
Max. applicable
motor output kW
Inverter model
CIMR - V7AZ
Figure
Dimensions in mm (inches)
Weight kg
Cooling
method
W H D W1 H1 H2 D1
Three-phase
200 V
5.5 25P5
3
180 260 170 164 244 8 65
4.6
Fan cooled
7.5 27P5 4.8
Three-phase
400 V
5.5 45P5
180 260 170 164 244 8 65
4.8
7.5 47P5 4.8
W 1
D
D1
8.5
(0.34)
W
H 2 H 1
H
2 M4
W 1
W
H 2 H 1
H
4 M4
D
8.5
(0.34)
D1
Figure 1 Figure 2
Figure 3
Frequency inverters 9

Other manuals for Omron V7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V7 and is the answer not in the manual?

Omron V7 Specifications

General IconGeneral
SeriesV7
Cooling MethodForced air cooling
Power Rating0.4kW to 15kW
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating, Short Circuit
Output Voltage3-phase 200 to 240 VAC, 3-phase 380 to 480 VAC