Varispeed J7 361
AC reactor
DC reactor
200 V class 400 V class
Max. applicable
motor output kW
Current value
A
Inductance
mH
Max. applicable
motor output kW
Current value
A
Inductance
mH
0.1 2.0 2.0 ------
0.22.02.00.2
1.3 18.0
0.42.54.20.4
0.75 5 2.1 0.75 2.5 8.4
1.5 10 1.1 1.5 5 4.2
2.2 15 0.71 2.2 7.5 3.6
4.0 20 0.53 4.0 10 2.2
200 V class 400 V class
Max. applicable
motor output kW
Current value
A
Inductance
mH
Max. applicable
motor output kW
Current value
A
Inductance
mH
0.12 5.4 8 --------
0.25 0.37 3.2 28
0.55 0.55
1.1 1.1
1.5 18 3 1.5 5.7 11
2.2 2.2
4.0 4.0 12 6.3
L1(R)
U
V
W
X
Y
Z
L2(S)
L3(T)
L1(R)
L2(S)
L3(T)
T1(U)
T2(V)
T3(W)
CIMR-J7AZ
MCCB
Motor
AC reactor
IM
Be sure to connect
AC reactor on inverter
input side [L
1 (R),
L
2 (S), L3 (T)].
CIMR-J7AZ
DC reactor
Motor
MCCB