PRECAUTIONS ON SAFETY
●Meanings of Signal Words
●Alert Statements in This Instruction Sheet
Indicates a potentially hazardous situation which, if not avoided, 
will result in minor or moderate injury, or may result in serious 
injury or death. Additionally, there may be significant property 
damage.
WARNING
When screw-fastening the body for use, vibration or the body’s own 
weight may cause it to fall, and cause an injury if the screws are not 
sufficiently tightened.
Mount the body using M5 screws tightened to a tightening torque of 
1.2 to 1.6 N.m.
Do not open the cace and insert your hand inside the body before the 
fan has stopped rotating. Doing so might cause an injury. 
Before opening the cace to replace the filter, always turn the power 
supply OFF, and make sure that the fan has stopped rotating.
WARNING
Please observe the following precautions for safe use of the product.
1. Do not use this product in environments where it can be exposed to 
inflammable/explosive gas. 
2. In order to secure the safety of operation and maintenance, do not 
install this product close to high-voltage devices and power devices. 
3. Use the power supply within the specified voltage range. 
4. Do not disassemble, repair, or modify this product.
5. Dispose of this product as industrial waste.
6.  Do not connect Ethernet with the communication terminal (RJ-45). 
The equipment might be damaged.
■ Applicable standards
・EN61326-1
・Electromagnetic environment : Industrial electromagnetic environment 
              (EN/IEC 61326-1 Table 2) 
PRECAUTIONS FOR SAFE USE
(1) AC adapter jack
     For connecting the AC adapter (Always use the exclusive AC adapter.)
(2) Power supply/output terminals
      Terminals for power input and alarm out put
      For wire used for a terminal block,consider the following.
      Wire length:30m and less
*1 Attached AC cord as standard is designed for use with 100 VAC (Japanese specications). When ZN-A4105 is 
used in other than Japan, ZN-A4105D should be selected. AC adapter and AC cord is not supplied with it, please 
connect DC power supply to terminal.
D
Keepterminal4alwaysbeingOFF.
3 Baud rate selection
Baud rate : 38.4kbps Baud rate : 19.2kbps
(6) ID rotary switch  
Used for  ID settings when communicating with RS-422/RS-485. Need to set the IDs in 
the following cases.
・ Connecting multiple ZN-As
・
Connecting with ZN-SF(Need to set IDs to ZN-As, even when connected with one ZN-A)
Give the different IDs to each ZN-As, and do not use "0" for ID number.
(Set an ID "0" only when the ZN-A is controlled by ZN-PDA. )
(7)   DIP switch
        Use this DIP switch when changing air volume changing method.
(4), (5)Terminal for communication (COMMUNICATION PORT) 
Use for communicating by RS-422/RS-485, or for connecting Air Particle Sensor 
ZN-PDA and Interface Unit ZN-SF(sold separately).
・When using Air Particle Sensor ZN-PDA or Interface Unit ZN-SF(sold separately),  set 
 RS-422 communication and connect to the IN side. 
 Regarding communication setting, please refer to "(7)DIP SW".
・
During RS-422 communication, 24 VDC is supplied to (4)IN side  communication terminal  
   (RJ-45) pin No.8. Do not connect Ethernet. The equipment  might be damaged. 
・When connecting multiple ZN-As during RS-422 communication, connect the (5) OUT 
   side to the next (4)IN side. (Don't connect the (4)IN side to each other.)
・Use straight type LAN cables for connecting between multiple ZN-As by RS-422 /
   RS-485 communication.
・The cable length between  devices must be 30m and less. The cables must be 100 m and 
   less in total length.
3 Baud rate selection Baud rate : 38.4kbps Baud rate : 19.2kbps
2 Filter stuck detection Filter stuck detection : Effective Filter stuck detection : Invalid
1
Air volume switching
method selection
Air volume is switched manually 
(air volume switching button on body)
The air volume is automatically controlled by feedback 
from Air Particle Sensor ZN-PDA and interface Unit
ZN-SF (sold separately).
DIP SW Function OFF ON
4
Communication
Settings
RS-422 RS-485
Filter clogging detection
Filter clogging detection : Effective Filter clogging detection : Invalid
Filter clogging detection
Filter clogging detection
the filter clogging detection display
Manual Air volume selectable (Level 1 to 5),
Air volume selectable by RS-422/RS-485 communication, 
Multi connection up to 9 units, Automatic control by ZN-PDA,
Filter clogging alarm, Available with ZN-J (Ionizer unit)
ZN-A4105    /  ZN-A4105D
*1
*1
Manufacturer:
  Omron Corporation,
  Shiokoji Horikawa, Shimogyo-ku,
  Kyoto 600-8530 JAPAN
 
TRACEABILITY INFORMATION:
Importer in EU:
  Omron Europe B.V.
  Wegalaan 67-69
  2132 JD Hoofddorp,
  The Netherlands
The following notice applies only to products that carry the CE mark:
Notice:
This is a class A product. In residential areas it may cause radio
interference, in which case the user may be required to take adequate
measures to reduce interference.
OMRON Corporation 2007 All Rights Reserved.OMRON Corporation 2007 All Rights Reserved.
ZN-A4105
Model
Air Clean Unit
INSTRUCTION SHEET
Thank you for selecting OMRON product. This sheet primarily 
describes precautions required in installing and operating the 
product.
Before operating the product, read the sheet thoroughly to acquire 
sufficient knowledge of the product. For your convenience, keep the 
sheet at your disposal.
Air clean unit makes the area that is enclosed less dust condition in the 
manufacturing environment. It is used to reduce defectives that are caused by dust 
in assemble process. It is possible to adjust air volume according to size or clean 
level of the area that needs to be kept clean.
 Intended purpose
Dispose in accodance withapplicableregulations.