EasyManua.ls Logo

Omron ZN-A Series - User Manual

Omron ZN-A Series
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Clean Sensing System
ZN Series
System Manual
Cat. No. Z267-E1-01
©OMRON Corporation 2007 All Rights Reserved.
Note: Specifications subject to change without notice.
Printed in Japan.
0707- 0.5C (0707) (M)
Authorized Distributor:
Cat. No. Z267-E1-01
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Application Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81) 75-344-7068/Fax: (81) 75-344-7107
Regional Headquarters
OMRON EUROPE B.V.
Sensor Business Unit
Carl-Benz-Str. 4, D-71154 Nufringen,
Germany
Tel: (49) 7032-811-0/Fax: (49) 7032-811-199
OMRON ELECTRONICS LLC
OMRON ASIA PACIFIC PTE. LTD.
No. 438A Alexandra Road # 05-05/08 (Lobby 2),
Alexandra Technopark, Singapore 119967
Tel: (65) 6835-3011/Fax: (65) 6835-2711
OMRON (CHINA) CO., LTD.
Room 2211, Bank of China Tower,
200 Yin Cheng Zhong Road,
Pu Dong New Area, Shanghai, 200120, China
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200
One Commerce Drive Schaumburg,
IL 60173-5302 U.S.A.
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787

Other manuals for Omron ZN-A Series

Questions and Answers

  • P
    prattjaniceAug 8, 2025
    What to do if there is no communication with personal computer using Omron ZN-A Accessories?
    • E
      Eric LambAug 8, 2025
      If you're experiencing no communications with your personal computer when using Omron Accessories, try turning the power supplies of the Interface Unit and Air Particle Sensor Amplifier Units off and then back on again. If communications still do not start after restarting the Sensor, check points (i) to (iv).
  • S
    Samuel HammondAug 12, 2025
    Why the BUSY indicator does not light up on Omron Accessories?
    • C
      Charles HernandezAug 12, 2025
      If the BUSY indicator isn't lighting up on your Omron Accessories, it could be due to a few reasons: * No signal is being sent to the Interface Unit: Ensure the sensor is connected with the correct cable and not a straight cable by mistake. * Confirm the sensor is correctly connected. * Verify that the correct communications port is set.
  • M
    Miss Madison RaymondAug 16, 2025
    How to match the communication ports for Omron Accessories?
    • D
      Dr. Melody Smith MDAug 17, 2025
      If the communications ports don't match when using Omron Accessories, set the same communications port number as that on the personal computer. Note that the other communications conditions are set automatically. Also, quit the application program that is using the communications port.
  • A
    Anthony GallowayAug 21, 2025
    What to do if the Air Particle Sensor power supply is not ON for Omron Accessories?
    • S
      Shannon VillanuevaAug 21, 2025
      If the Air Particle Sensor power supply is not ON for Omron Accessories, check the power supply voltage if the DC power supply is used and ensure all cables are connected correctly.
  • L
    Lydia GonzalesAug 25, 2025
    What to do if the Air Clean Unit power supply is not ON for Omron Accessories?
    • P
      Patricia MercadoAug 26, 2025
      If the Air Clean Unit power supply is not ON for Omron Accessories, check the power supply voltage if the DC power supply wire is used and ensure that the AC adapter (provided) is used.
  • A
    anthonygarzaAug 29, 2025
    What to do if there is no response from the Interface Unit of Omron Accessories?
    • T
      Tracey KellyAug 29, 2025
      If there is no response from the Interface Unit with Omron Accessories, ensure the switch on the rear of the Interface Unit is set to the default side and that the mode switch on the Air Particle Sensor's Amplifier Unit is set to RUN.
  • J
    joelwilliamsSep 2, 2025
    What to do if the sensor communications LED does not light on Omron ZN-A?
    • G
      gregorytravisSep 2, 2025
      If the sensor communications LED or the external terminal communications LED ERR indicator does not light even after 5 seconds has elapsed for Omron Accessories, make sure the mode switch on the Air Particle Sensor Amplifier Unit is set to RUN. Also, check if the Amplifier Units are connected correctly to each other, and if the Interface Unit is connected correctly to the Amplifier Unit. Finally, verify that the Amplifier Unit has started up properly.

Omron ZN-A Series Specifications

General IconGeneral
BrandOmron
ModelZN-A Series
CategoryAccessories
LanguageEnglish

Related product manuals