J
Jamie SanchezAug 18, 2025
What to do if the Omron Accessories Sensor Head is disconnected or shows an error?
- AArthur HallAug 18, 2025
If the Sensor Head is disconnected, connect it. If the issue persists, replace the Sensor Head.
 

What to do if the Omron Accessories Sensor Head is disconnected or shows an error?
If the Sensor Head is disconnected, connect it. If the issue persists, replace the Sensor Head.
How to fix EEPROM destruction or data error on Omron ZX-LD30V?
To fix an EEPROM destruction or data error, press the ENT Key for 3 seconds or longer. If this doesn't work, replace the Amplifier Unit.
What to do if Omron ZX-LD30V Accessories shows incident level insufficient or distance measurement error?
If you are experiencing an insufficient incident level or distance measurement error, optimize the gain setting or select the AUTO mode when changing the gain setting. If the problem persists, change to an appropriate workpiece.
What to do if Omron ZX-LD30V shows incident level saturation or distance measurement error?
If you are experiencing incident level saturation or a distance measurement error, optimize the gain setting or select the AUTO mode when changing the gain setting. If the problem persists, change to an appropriate workpiece.
Why am I getting a distance error on my Omron Accessories?
If you're getting a distance error, ensure the workpiece is within the measurable range.
What causes two-sensor operation communication data error in Omron ZX-LD30V Accessories?
A two-sensor operation communication data error may occur. Try the following: 1. Select the T or RUN Mode for the 1CH Amplifier Unit. 2. Check whether a incident level error has occurred for the 1CH Amplifier Unit. 3. Check whether the connection between the Amplifier Units is normal. If the issue persists, replace the Amplifier Unit or the Calculating Unit.
What to do if I attempted to set a numeric value larger than the HIGH threshold value to the LOW threshold value on Omron Accessories?
If you've attempted to set a numeric value larger than the HIGH threshold value to the LOW threshold value, reset the threshold values, referring to 5-2-3.
What to do if I attempted to set a numeric value smaller than the LOW threshold value to the HIGH threshold value on Omron ZX-LD30V Accessories?
If you've attempted to set a numeric value smaller than the LOW threshold value to the HIGH threshold value, reset the threshold values, referring to 5-2-3.
What to do if one or all of the judgement outputs are short-circuited on Omron ZX-LD30V Accessories?
If one or all of the judgement outputs are short-circuited, clear the load short-circuit.
What to do if the set numeric value is too large on Omron Accessories?
If the set numeric value is too large, input an appropriate numeric value.
| Type | Laser Displacement Sensor | 
|---|---|
| Ambient humidity | 35 to 85% RH (No condensation) | 
| Weight | Approx. 100 g | 
| Linearity | ±0.1% of F.S. | 
| Light source | Semiconductor laser | 
| Laser class | Class 2 | 
| Measurement Range | ±5 mm | 
| Output Type | Analog voltage | 
| Power Supply Voltage | 12 to 24 VDC ±10% (ripple: 10% p-p max.) | 
Covers OMRON's product warranty, liability limitations, and suitability for intended use.
Explains safety conventions (WARNING, CAUTION) and the importance of heeding safety information.
Details precautions for safe use of laser radiation, including eye protection and housing integrity.
Details procedures for connecting sensor heads, amplifier units, and installing them.
Covers scaling, hysteresis, hold functions, timers, and two-sensor operations for reflective sensors.