What to do if the Omron ZX-LDA11 Sensor Head is disconnected or shows an error?
- RRachel FrancoAug 19, 2025
If the Sensor Head is disconnected, connect it. If the issue persists, replace the Sensor Head.
What to do if the Omron ZX-LDA11 Sensor Head is disconnected or shows an error?
If the Sensor Head is disconnected, connect it. If the issue persists, replace the Sensor Head.
How to fix EEPROM destruction or data error on Omron ZX-LDA11 Accessories?
To fix an EEPROM destruction or data error, press the ENT Key for 3 seconds or longer. If this doesn't work, replace the Amplifier Unit.
What to do if Omron ZX-LDA11 shows incident level insufficient or distance measurement error?
If you are experiencing an insufficient incident level or distance measurement error, optimize the gain setting or select the AUTO mode when changing the gain setting. If the problem persists, change to an appropriate workpiece.
What to do if Omron ZX-LDA11 Accessories shows incident level saturation or distance measurement error?
If you are experiencing incident level saturation or a distance measurement error, optimize the gain setting or select the AUTO mode when changing the gain setting. If the problem persists, change to an appropriate workpiece.
Why am I getting a distance error on my Omron ZX-LDA11?
If you're getting a distance error, ensure the workpiece is within the measurable range.
What causes two-sensor operation communication data error in Omron ZX-LDA11 Accessories?
A two-sensor operation communication data error may occur. Try the following: 1. Select the T or RUN Mode for the 1CH Amplifier Unit. 2. Check whether a incident level error has occurred for the 1CH Amplifier Unit. 3. Check whether the connection between the Amplifier Units is normal. If the issue persists, replace the Amplifier Unit or the Calculating Unit.
What to do if I attempted to set a numeric value larger than the HIGH threshold value to the LOW threshold value on Omron ZX-LDA11 Accessories?
If you've attempted to set a numeric value larger than the HIGH threshold value to the LOW threshold value, reset the threshold values, referring to 5-2-3.
What to do if I attempted to set a numeric value smaller than the LOW threshold value to the HIGH threshold value on Omron ZX-LDA11?
If you've attempted to set a numeric value smaller than the LOW threshold value to the HIGH threshold value, reset the threshold values, referring to 5-2-3.
What to do if one or all of the judgement outputs are short-circuited on Omron ZX-LDA11?
If one or all of the judgement outputs are short-circuited, clear the load short-circuit.
What to do if the set numeric value is too large on Omron ZX-LDA11 Accessories?
If the set numeric value is too large, input an appropriate numeric value.
Brand | Omron |
---|---|
Model | ZX-LDA11 |
Category | Accessories |
Language | English |
Summary of manufacturer's requirements for laser product safety standards.
Precautions for the safe operation and use of laser products.
Details scaling, hold functions, timers, and two-sensor operations for reflective sensors.
Details auto-scaling, hysteresis, hold functions, and two-sensor operations for through-beam sensors.
Details changing functions, set values, key lock, scaling, and initialization settings.
Describes common setting problems like inability to set scaling, monitor focus, or threshold values.
Provides detailed specifications for reflective, through-beam sensors, amplifier units, and calculating units.