Onan CCK Series - Service Diagnosis Continued; Engine Misfires at All Loads; Low Oil Pressure Issues; High Oil Pressure Issues

Onan CCK Series
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
82 S
ERYIC
E
DIAGNOSIS
POSSIBLE CAUSE REMEDY
ENGINE MISFIRES AT
HEAVY
LOAD (Cont. )
Clogged
fuel·screen.
Clean.
Defective
spark
plug
cable.
Replace.
ENGINE MlSFIRES AT
ALL
LOADS
Fouled
spark
plug.
Defective
or
wrong
spark
plug.
Leaking
valves
.
Broken
valve
spring.
Defective
or
impropedyad-
justed
breaker
points.
Clean
and
adjust.
Replace.
Grind
valves.
Replace.
Adjust
or
replace
breaker
points.
LOW
OIL PRESSURE
Oil
too
. light
or
diluted
from
Drain,
refill
with
proper
oil.
Re-
leaking
fuel pump diaph:ragm.
pair
or
r.eplace
fuel
pump.
Oil
too
low.
Add
oil.
Oil
relief
valve
not
seating.
Remove
and
clean,
or
replace.
Badly
worn
bearings.
Replace.
Sludge on
oil
screen.
Remove
and
clean.
Badly
worn
oil
pump.
Replace.
Defective
oil
pressure
gauge.
Replace.
HIGH OIL PRESSURE
Oil
too
heavy.
Drain,
refill
with
proper
oiL
Clogged
oil
passage.
.
Clean
aU· lines. and paiilsages.
Oil
relief
valve
stuck.
Remove and cJean.
Defective
011
pressure
gauge.
Replace.

Other manuals for Onan CCK Series

Related product manuals