Openpath ACUs (Controller Boards/Cores and Expansion Boards) have several LEDs
that indicate the following:
POWER LEDs indicate that the board is connected to power
RELAY LEDs indicate when the relays are activated
STATUS LEDs indicate that the ACU has been configured with firmware. It will
flash green when Identify is pressed in the Control Center.
On the 4-Port and 8-Port Boards, the STATUS LED is solid green when it is
connected and communicating with the Core, and solid red when there
is a connection error
If the STATUS LED is solid red, try the following:
Power cycle 4-Port/8-Port
Unplug and replug USB cable
Restart Hardware Communicator in Control Center
The STATUS LED on the Core Board has several states, see CORE STATUS
LED
READER POWER LEDs indicate that the ACU has output power enabled per
reader
BOARD ID LEDs match the Expansion Board Number in the Control Center
CORE STATUS LED
The Core’s STATUS LED indicates the following:
Solid Green indicates the Core is provisioned and functioning normally
Blinking Red indicates there is a problem with the Internet connection
Solid Cyan appears when the Core is booting
Solid Yellow indicates that the Core is restoring software; appears when you
power on the Core for the first time
Blinking Yellow indicates that the Core is updating software; appears when
the Core has been online for less than 24 hours
Solid Blue indicates that the Core has finished booting and is ready for
provisioning
Solid Purple indicates that the Core is connected to the Open Admin app
Blinking Purple indicates the Core is ready to connect to the Open Admin app
Solid Red indicates the Core is in an error state–go to the Hardware
Dashboard in the Control Center for more information