2. Description: release an existing serial port
3. Input(s) controllerHandle the handle of the controller
4. Return value:
succeed: OPT SUCCEED;
failed: OPT ERR RELEASESERIALPORT FAILED (see the error code in Tab. 1).
5. See also: initializing a serial port
2.3. Creating an Ethernet connection (by IP)
1. Function: long OPTController CreateEtheConnectionByIP(char *serverIPAddress, OPTController Handle
*controllerHandle)
2. Description: create an Ethernet connection by IP address
3. Input(s) char *serverIPAddress the IP of the server. e.g., IP address of the device which is employed
as server§The server IP address can be 127.0.0.1
4. Output(s): controllerHandle the handle of the controller
5. Return value
succeed: OPT SUCCEED;
failed: OPT ERR CREATEETHECON FAILED (see the error code in Tab. 1).
6. Remarks: connect to a server as a client. Before connecting, make sure that the controller is connected
to the LAN.
7. See also: destroying an Ethernet connection
2.4. Creating an Ethernet connection (by SN)
1. Function: long OPTController CreateEtheConnectionBySN(char *serialNumber, OPTController Handle
*controllerHandle)
2. Description: create an Ethernet connection by serial number
3. Input(s) serialNumber the serial number of the controller
4. Output(s): controllerHandle the handle of the controller
5. Return value
succeed: OPT SUCCEED;