Unit: mm (inch)
- Dimensions
with bracket
62.2 (2.45)
159.1 (6.26)
55.7 (2.19)
124.5 (4.90)
15
- Events and responses
Events
Anti-masking detection
Local self test
Walk test
Low voltage detection
Triggered by
Objects close to the lens surface over 20 sec.
Controlled by detector’ s circuit periodically.
(PIR and Microwave are tested at the same time.)
Conduct a walk test at least once a year.
Voltage drop.
Output & Remarks
Alarm and Trouble signals.
Fail; Trouble signal.
(Detector doesn't work for about 10 seconds during local self test.)
Keep at least 1 meter from the detector and clear of any objects.
Trouble signal
167 (6.57)
107.1 (4.22)
- LED indications
Warm-up
Masking detection
Alarm
PIR detection
MW detection
Self test error
Low voltage
2 s
2 s
2 s
Multiple,60 s
Green, Repeats
Yellow, Repeats
Red, repeats