EasyManuals Logo

Optex VX-402R User Manual

Optex VX-402R
6 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Safety-Related Precautions
Denotes a situation involving the risk of serious injury or damage to property if
the warning is ignored.
Caution
This icon denotes a situation involving the risk of serious injury or even death, if the
warning given is ignored.
Warning
This icon indicates actions to be avoided. Details of the actions to be avoided are written beside or near icon.
This icon indicates instructions that should be strictly followed.
Never use this product for any application except purpose for detecting
moving target such as a human or a car. In addition, never use for any
activation for a shutter or other. It may cause hazards.
Clean and inspect the device periodically for safe operation.
If any defect is detected, ask your local supplier to repair the device.
To avoid the risk of damaging the product, never touch the main body of the
product with wet hands. (Also, if the product is wet after rain do not touch it)
Never attempt to connect the terminals to units which reguire higher power
supply or current draw than its rating. It increases the risk of fire or damage
to the product.
Never attempt to disassemble or modify the product, which increases the risk
of fire or damage of the product.
Avoid applying water in directly from brackets, houses, or otherwise splash-
ing water directly onto the product. It increases the risk of damaging the
product.
Warning
Caution
·Before installation,make sure to read this instruction manual carefully for safe and effective product operation.
·After reading this installation manual, make sure to keep it in a convenient place for future use.
If the sensor is installed with some angle
to the ground, operational reliability of
the sensor may be decreased.
1.INSTALLATION HINTS
Avoid pointing the sensor towards moving
objects (i.e. swaying trees, bushes,
flags,etc.).
If moving objects are unavoidable, please
refer to TROUBLE SHOOTING reference
for proper installation.
1.Perpendicular Installation
Select a place for installing the VX-402R while keeping the following points in mind.
2. Installation height
0.8m-1.2m
VX-402R is designed to protect any light
disturbances.
However , too much light such as; strong
sunlight directed or reflected exactly into the
sensor’s field of view may cause unstable
operation. It is recommended to avid installing
in such a place.
The detection area has directionality.
Mount the detector so that it must be
passed in order to gain entry.
3.Detection Area Setup
Parallel
Install the sensor perpendicular to the
ground to making upper detection area
parallel to the ground.
Installation height is
0.8m-1.2m (2.7ft-4ft)
·Low Current Draw
·Battery Saving Circuit
·Operates on Wide Range of Power
·Back box for a wireless transmitter
·Limited Detection Range Function
·Size Judging Function
·Bright Light Disturbance Immunity
10uA (In Standby).
The alarm circuit will not be activated untill there is a 5 or 120 seconds period of inactivity in the pattern area.
3-9V Alkaline Battery or Lithium Battery.
Backbox can conceal a wireless transmitter circuitboad (W63mm x H140mm x D31mm).
The detection range of the VX-402R can be limited to avoid detecting unwanted objects. By limiting the
detection range, false alarms due to unwanted movement ( i.e. cars, persons or animals outside the
protected area ) can be reduced.
VX-402R is designed to discriminate between large and small animals. By utilizing this ability, false alarms
due to small animals can be reduced.
VX-402R is equipped with Double Conductive Shielding (Patent Listed). This shielding greatly reduces the
chance of false alarms due to car headlights, sunlight and other ambient light sources.
VX-402R
BATTERY OPERATED
FEATURES
VX-402R
MULTI STABILIZED OUTDOOR DETECTOR
BATTERY OPERATED
No.59-1048-1 0209-18
2 YEAR WARRANTY

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Optex VX-402R and is the answer not in the manual?

Optex VX-402R Specifications

General IconGeneral
Sensor typePassive infrared (PIR) sensor
Connectivity technologyWireless
Static current0.01 mA
Battery voltage9 V
Power consumption3 mA
Power source typeBattery
Battery technology-
Rechargeable batteryYes
Operating temperature (T-T)-20 - 50 °C
Package typeBox
SwitchForm C-Solid
LED colorRed
PlacementOutdoor
CertificationEMC 89/336 EEC
Mounting typeWall
Product colorWhite
Housing materialPlastic
Installation height (max)2 m
Installation height (min)0.8 m
International Protection (IP) codeIP54
Weight and Dimensions IconWeight and Dimensions
Depth108 mm
Width80 mm
Height198 mm
Weight480 g