Press and slide the detection length adjustment switch to the desired position.
Detection Length
Adjustment Switch
*The maximum detection length may vary
as above due to environmental thermal
conditions.
Detection Length setting chart
Standard
12.0 10.0 - 15.0
(40.0) (33.3 - 50.0)
8.0 6.0 - 10.0
(26.7) (20.0 - 33.3)
5.0 4.0 - 5.5
(16.7) (13.3 - 18.3)
2.0 1.5 - 2.5
(6.7) (5.0 - 8.3)
C
D
*
MAX DETECTION LENGTH
A
B
POSITION
5-3.Area Masking
1.Remove the lens holder
from the cover as
shown above.
5-2.Area Angle Adjustment
Active detection fingers.
45degree adjustable
45degree Adjustable
Top view
Area angle is 90degree with
7 fingers by 15degree per
notch.
(If you want to reduce the number
of fingers, fasten the lens with
the area masking plate provided.)
Hold the pyro electric
unit and turn it to the
desired direction
(15degree steps).
45•‹
90•‹
45•‹
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)(12)(13)
Lens and area correspon-
dence as seen from the inside
3.Put the lens back in by
aligning the 4 projections on
the cover to the 4 cut outs
on the lens.
(The lens has vertical
orientation. Be sure the lens is
correctly orientated when
mounting.)
2.Separate the lens from
the cover. Apply the
provided area masking
plate to the inside of the lens
on the zone to be eliminated.
4.Mount the lens holder. make
sure the lens holder is held
by left and right prongs on
the cover.
(Make sure the tabs [2] on the left
and right are engaged.)
(4)
Projection
(2)
(1) (3)
Projection
POSITION A (0-12m)
POSITION B (0-8m)
0 5 10 12 m
POSITION C (0-5m)
POSITION D (0-2m)
0 5 10 12 m
0 5 10 12 m
0 5 10 12 m
1m
1m
1m
1m
Instration Height=1m (3.3ft)
5-1.Detection Length Adjustment
5.SETTING & ADJUSTMENTS
Length of Lower Detecion Area decides detection length
The upper detection area stays parallel to the ground at all time. The lower detection area moves as shown above depending on the switch
position. Detection length is therefore limited by the length of lower detection area, since both upper and lower detection area have to be
blocked at the same time to activate the sensor.
Detection Length
NO
Detection
Only upper detection
area is blocked
Detection Length
Both upper and lower
detection area are
blocked!
Detection!
Detection Length
Only lower detection
area is blocked
NO
Detection
·This product detects temperature differences between the moving object and the background temperature in the detection
area. If the object does not move, the detector can not detect it.
·This product has directional characteristic it is difficult to detect the target that is approaching the detector.
·If there is a traffic near the dettection area, please adjust detectiion 1.5m to 2.0m (5ft to 7ft) away from movements.
IMPORTANT!
As shown above 5-2, there are always 7 active detection fingers. If the area masking plate is not applied, the active fingers
are varied by area adjustment as explained at left.
Please check which fingers are active before applying area masking plate.
IMPORTANT!
m(ft.)