TEC32-1664-009 OceanTRx7™ ADMx Technical Note Page 10 of 10
4 Post replacement check
After the ADMX has been replaced, perform the following test procedures to verify system
functioning.
1. Start up the system (see the
OceanTRx7™ Installation and Operation Manual
for
instructions).
2. Verify that there are no ERR/WRN system messages and that there is communication
between the CCU and the ACU.
3. Perform 1dbcp with the NOC and confirm the system is back online.