56 Orion LX Weather Station
____________________________________________________________________
Chose the output format desired. The output format is dependent on how
the data is going to be used at the FTP server.
XML (Extensible Markup Language) is a data description file that also
contains the data. The XML file will contain the current measurements.
This format is useful for generating web pages containing the weather
data and for interfacing with other software programs.
CSV (comma-separated values) file contains the data separated by
commas. The field order in the record is based on the same order of the
selected measurements in the Select Measurements page. Two output
formats are available:
CSV-append data format will generate a file with comma-separated
records every 15 seconds without overwriting the previous data.
CSV-overwrite data format will generate a file with one (the latest)
comma-separated record. This file will update every 15 seconds and
overwrite the previous record.
Diagnostic Logging
Is set to Verbose Logging by default. The diagnostic logging is used by
Customer Service to troubleshoot problems with the MicroServer.
SNMP Output
SNMP: Simple Network Management Protocol. The Orion LX Weather
MicroServer has a built-in SNMP interface for communication with
network management systems.
Click on Show MIB file to view the MIB definitions and objects for the
Orion LX MicroServer.
Modbus TCP Output
The Orion LX Weather MicroServer has a built-in Modbus TCP/IP slave
interface for communication with industrial automation systems and OPC
servers.
All data accessed via (read only) input registers [Modbus function code
3].
Contact us for a complete Modbus point list document.

Table of Contents