DIGITAL ELECTRONIC TEMPERATURE
CONTROLLER WITH DEFROSTING
FUNCTION
F 10
USER MANUAL - V1
www.osakasolutions.com
PREFACE
j
This manual contains the information necessary for the
product to be installed correctly and also instructions for
its maintenance and use; we therefore recommend that
the utmost attention is paid to the following instructions
and to save it
This document is the exclusive property of Osaka Solutions, S.L.
which forbids any reproduction and divulgation, even partially,
of the document, unless expressly authorized.
Osaka Solutions,
S.L. reserves the right to make any formal or
functional changes at any moment and without any notice.
j
Osaka Solutions, S.L. and its legal representatives do
not assume any responsibility for any damage to peo-
ple, things or animals deriving from violation, wrong or
improper use or in any case not in compliance with the
instrument features.
j
Whenever a failure or a malfunction of the device may
cause dangerous situations for persons, thing or animals,
please remember that the plant has to be equipped with
additional electromechanical devices which will guaran-
tee safety.
1. INSTRUMENT DESCRIPTION
1.1 General description
The model F 10 is a microprocessor based digital electronic
temperature controller that is typically used in cooling applica-
tions with ON/OFF temperature control and defrost control
with intervals time by stopping compressor
The instrument has 1 relay output and 2 NTC temperature
probes inputs one of which can be configured as digital input;
it can also be equipped with a built-in buzzer for acoustic report
of the alarms.
Index
1. Instrument description ....................................................... 1
1.1 General description ..............................................................................1
1.2 Front panel pescription .......................................................................2
2. Programming ....................................................................... 2
2.1 Fast Set point programming ..............................................................2
2.2 Standard mode parameters programming ................................... 2
2.3 Parameter protection using the password ...................................3
2.4 Customized mode parameter programming
(parameters programming level) ......................................................3
2.5 Reset parameters to default value ..................................................3
2.6 Keyboard lock function ........................................................................3
3. Usage warnings ................................................................... 3
3.1 Admitted use ..........................................................................................3
4. Installation warnings .......................................................... 4
4.1 Mechanical mounting ..........................................................................4
4.1.1 Mechanical dimensions, panel cut-out and mounting [mm] .................... 4
4.2 Electrical connections ..........................................................................4
4.2.1 Electrical wiring diagram .................................................................................................. 4
5. Functions ............................................................................. 4
5.1 ON/Stand-by function ......................................................................... 4
5.2 Normal and economic operation ......................................................5
5.2.1 Normal/Economic operation selection ................................................................... 5
5.3 Measure and display configuration .................................................5
5.4 Digital input configuration ..................................................................5
5.5 Temperature control.............................................................................6
5.6 Compressor protection function and power-on delay ...............6
5.7 Defrost control .......................................................................................6
5.7.1 Manual defrost ........................................................................................................................ 7
5.7.2 Display lock during Defrosting ...................................................................................... 7
5.8 Alarm functions .....................................................................................7
5.8.1 Temperature alarms ............................................................................................................ 7
5.8.2 External alarm from digital input ................................................................................ 8
5.8.3 Open door alarm .................................................................................................................... 8
5.9 Function of keys and / ...................................... 8
5.10 Parameters configuration by “KEY USB” .......................................8
6. Programmable parameters table ....................................... 9
7. Problems, maintenance and warranty............................. 10
7.1 Notifications ........................................................................................ 10
7.1.1 Error messages ....................................................................................................................10
7.1.2 Other messages...................................................................................................................10
7.2 Cleaning ................................................................................................ 10
7.3 Warranty and Repairs ....................................................................... 10
7.4 Disposal ................................................................................................ 10
8. Technical data .................................................................... 10
8.1 Electrical characteristics .................................................................. 10
8.2 Mechanical characteristics .............................................................. 10
8.3 Functional features ........................................................................... 11
WWW.OSAKASOLUTIONS.COM
m
m
m
Question and Answer IconNeed help?

Do you have a question about the Osaka F 10 and is the answer not in the manual?

Osaka F 10 Specifications

General IconGeneral
MountingPanel mount
Input TypeThermocouple, RTD
Control OutputRelay, SSR drive, Current
Number of Control Outputs1
Alarm Output1
Power Supply100 to 240 VAC 50/60 Hz
DisplayLED
Setting Resolution1°C
Ambient Temperature50°C
Dimensions48x48mm

Summary

Instrument Description

Front panel description

Details the functions and labels of each button, LED, and display element on the front panel.

Programming

Fast Set point programming

Explains how to quickly adjust the set point value using the front panel buttons.

Standard mode parameters programming

Describes the procedure to access and modify instrument parameters via the front panel interface.

Usage Warnings

Admitted use

Outlines the intended and safe usage conditions for the instrument, including altitude and environment restrictions.

Installation Warnings

Mechanical mounting

Provides instructions and dimensions for physically installing the instrument into a panel.

Electrical connections

Guides on wiring the instrument, including power supply, inputs, and outputs, with safety notes.

Functions

Temperature control

Describes the ON/OFF control action based on probe measurement, setpoint, and hysteresis.

Compressor protection function and power-on delay

Details features to prevent frequent compressor starts and manage start-up delays.

Defrost Control

Alarm Functions

Temperature alarms

Covers setting and managing high and low temperature alarms based on probe measurements.

Problems, Maintenance and Warranty