EasyManua.ls Logo

Osburn MATRIX - Page 41

Osburn MATRIX
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Matrix Insert Installation and Operation Manual
_______________________________________________________________________________41
CLEARANCES
F
16" (406
mm)
G
12" (305
mm)
H
20" (508
mm)
I
22"
(559
mm)
*
MINIMUM MASONRY
OPENING
J 23 3/4" (603 mm)
K 28 7/8" (733 mm)**
L
19 5/8
" (4
98
mm) ***
MAXIMUM THICKNESS
O 12" (305 mm)
P 1" (25 mm)
FLOOR PROTECTION
CANADA USA
B 18" (457 mm) – Note1 16" (406 mm) – Note 1
M 8" (203 mm) N/A (Canada only)
N N/A (USA only) 8" (203 mm)
Minimum floor to ceiling clearance: 84" (213 cm)
* For a 8" (203 mm) mantel shelf. See Section 8.3 Compliance of a Combustible Mantel Shelf
for other mantel shelf dimensions.
** Where a fresh air intake is needed, we suggest you add a minimum of 4’’ to the width of the
minimum masonry opening.
*** If projection kit AC01323 (sold separately) is used L = 17 5/8" or 15 5/8". If installed without
projection kit L = 19 5/8".
Note 1: From door opening. The depth of the hearth extension in front of the insert is included in
the calculation of the floor protector’s dimensions.

Table of Contents

Related product manuals