EasyManua.ls Logo

Oval Flowpet-5G Series - User Manual

Oval Flowpet-5G Series
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Ins. No.
S
-
179
-
1-E
ELECTRONICS REGISTER PROVIDED
FLOWPET
-5G
Water service
MODELLS5277-5B, LS5377-5 B, LS5577-5 B, LS5677-5B
Oil service
MODELLS4976-5 , LS5076-5 , LS5276-5 , LS5376-5 , LS5576-5 , LS5676-5
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
A
B
Ins. No. S
-
179
-
1-E
ELECTRONICS REGISTER PROVIDED
FLOWPET
-5G
Water service
MODELLS5277-5B, LS5377-5 B, LS5577-5B, LS5677-5 B
Oil service
MODELLS4976-5 , LS5076-5 , LS5276-5 , LS5376-5 , LS5576-5 , LS5676-5
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
A
B
上海洪柯自动化仪表有限公司
OVAL总代理: 上海洪柯自动化仪表有限公司 电话: 021-54485672 网址: WWW.SHAKIC.COM Email: shakic@163.com

Questions and Answers

  • R
    Ryan FarmerAug 12, 2025
    Why is the accumulated total high on my Oval Flowpet-5G Measuring Instruments?
    • T
      Tammy HicksAug 12, 2025
      If the accumulated total on your Oval Measuring Instruments is too high, it could be due to several reasons. The rotors might be rocking due to pulsating flow, in which case you should add a check valve and accumulator. External magnetic fields from motors or generators might be influencing the meter sensor; try removing these external magnetic fields. Finally, air entrapment could be the issue, so ensure you provide an air vent.
  • M
    Mitchell AndersonAug 16, 2025
    What to do if my Oval Measuring Instruments count while valves are closed?
    • E
      Emily HarrisAug 16, 2025
      If your Oval Measuring Instruments are counting even when the valves are closed and there is no fluid flow, it could be due to liquid leaks or air pockets between the valve and the meter, causing the rotors to oscillate from pump ripple pressures. To resolve this, provide an air bleed. Alternatively, install a check valve and accumulator.
  • L
    Lori MoodyAug 20, 2025
    How to fix liquid leaks in Oval Flowpet-5G Measuring Instruments?
    • N
      Nicole ButlerAug 20, 2025
      If your Oval Measuring Instruments are leaking liquid, first, retighten the pipe connections, as the sealing may be improper. If the leak persists, replace the O-ring on the meter body cover.
  • D
    Diane HuntAug 23, 2025
    How to troubleshoot fluid flow problems in Oval Flowpet-5G Measuring Instruments?
    • I
      irobbinsAug 23, 2025
      If fluid is not flowing through your Oval Measuring Instruments, check the following: First, ensure that the protective covers over the inlet and outlet flanges of the meter have been removed. If not, remove the meter and take off the covers. Second, scales may have jammed the oval rotors, preventing rotation; in this case, separate the register, disassemble, and clean the meter body. Lastly, the pump pressure or head pressure may be too low. Choose a pump that is better suited to your application, considering the pressure loss of the entire piping system.
  • J
    justin70Aug 27, 2025
    What to do if liquid flows but the register fails to count on Oval Flowpet-5G?
    • K
      Kristin BowmanAug 27, 2025
      If the register on your Oval Measuring Instruments fails to count even when liquid is flowing, the rotors may be installed backwards. Disassemble the meter body and reinstall the rotors so that the magnets on the rotor face the meter body cover.
  • S
    sabrina91Aug 31, 2025
    Why is the accumulated total low on my Oval Flowpet-5G Measuring Instruments?
    • J
      Jeremy GambleAug 31, 2025
      If the accumulated total on your Oval Measuring Instruments is too low, it might be influenced by external magnetic fields. Try to remove these external magnetic fields.
  • C
    Charles WatkinsSep 4, 2025
    What to do if the LCD counter fails to count on Oval Flowpet-5G?
    • K
      Kathy SuarezSep 4, 2025
      If the LCD counter on your Oval Measuring Instruments (b1, b2 modes) fails to count, it could be due to a low flowrate. Carefully open the valve to increase the flow. If fluid is not flowing, refer to Symptom 1.
  • T
    Thomas MorrowSep 7, 2025
    Why is there a steady-ON on the LCD of my Oval Flowpet-5G?
    • A
      Amanda CollierSep 7, 2025
      If a steady-ON “ ” is displayed on the LCD of your Oval Measuring Instruments, it means the battery voltage has dropped. Replace the flowmeter, the counter unit, or the battery unit within a week.

Summary

Handling Precautions

Confirming the Nameplate

Verify product code and specifications against the nameplate for correct configuration.

Transportation Precautions

Guidelines for safely transporting the instrument to prevent damage during transit.

Installation Location Precautions

Advice on selecting a suitable and safe location for meter installation.

Operating Conditions

Piping

Piping Precautions

Essential guidelines to ensure correct and safe installation, avoiding pipe strain and ensuring proper flow.

Changing Flow Directions and Display Orientations

Wiring

Field Wiring

Guidance on cable types, transmission lengths, and routing for optimal signal integrity.

Hook-up Diagrams

Display and Controls

Operation

Operation

Step-by-step guide for initiating operation, including valve sequencing and warm-up.

Troubleshooting

Error Messages

Explains various error codes displayed on the LCD and their corrective actions.

Disassembly and Inspection

Exploded View and Service Parts List

Ordering Replacement Parts

Battery Replacement and Parameter Setting

Battery Replacement

Step-by-step instructions for safely replacing the internal lithium battery unit.

Parameter Setting Procedure

Parameter Setup Procedure

Detailed guide on using MODE and RESET buttons to navigate and set various operational parameters.

Analog Output Trim Procedure

General Specifications

Oval Flowpet-5G Series Specifications

General IconGeneral
BrandOval
ModelFlowpet-5G Series
CategoryMeasuring Instruments
LanguageEnglish