  • A
    arroyoleslieAug 10, 2025
    Why does the LCD on my Oval FLOWPET-EG LS5076-4 0D show a steady-ON symbol?
    • J
      Jimmy LeeAug 10, 2025
      If the Oval Measuring Instruments show a steady-ON “ ” on the LCD, it means the battery voltage has dropped. Replace the flowmeter, the counter unit or battery unit within a week.
  • A
    Anthony BentleyAug 19, 2025
    What to do if fluid will not flow through my Oval FLOWPET-EG LS5076-4 0D?
    • R
      Robert MarshallAug 19, 2025
      If fluid won't flow through your Oval Measuring Instruments, several issues could be the cause. First, check if the pipes were connected without removing the protective covers over the inlet and outlet of flanges of the meter; if so, remove the meter and take off the covers. Second, scales may have jammed the oval rotors, preventing rotation; in this case, separate the register, disassemble, and clean the meter body. Finally, low pump or head pressure could be the issue; consider the pressure loss of the entire piping system and choose a more suitable pump for your application.
  • I
    iwoodAug 28, 2025
    How to fix liquid leaks in my Oval FLOWPET-EG LS5076-4 0D?
    • H
      Holly MorrisAug 29, 2025
      If your Oval Measuring Instruments are leaking liquid, it could be due to improper sealing. Try retightening the pipe connections. Another possible reason is that the rotors are installed backward. To fix this, disassemble the meter body and reinstall the rotors so that the magnets on the rotor will face the meter body cover.

Summary

HANDLING PRECAUTIONS

1.2 Transportation Precautions

Guidelines for safe transport to prevent damage during transit.

1.4 Installation Location Precautions

Important considerations for selecting an appropriate installation site.

PIPING

4.1 Piping Precautions

Essential guidelines and precautions for connecting the meter to piping systems.

WIRING

5.3 Hook-up Diagrams

Provides circuit diagrams for connecting the flowmeter output signals.

DISPLAY AND CONTROLS

6.2 Display Capabilities and Operation

Describes the functions of the register, LCD display, and pulse generator.

OPERATION

7.1 Operation

Step-by-step guide for safe and correct operation of the flowmeter.

DISASSEMBLY AND INSPECTION

Meter Body Disassembly and Inspection

Procedures for periodic disassembly and inspection of the meter body.

BATTERY REPLACEMENT AND FACTOR SETTING PROCEDURE

11.1 Battery Replacement

Step-by-step instructions for replacing the battery unit in the register.

11.2 Parameter Setting Procedure

Guide on how to set or change various parameters like units, pulse weight, etc.