EasyManua.ls Logo

Oval FLOWPET-EG LS4976-4 0A Series User Manual

Default Icon
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Ins. No. S
-
178
-
10
S
-
178
-
10
-
E
電子式計数部付
ELECTRONICS REGISTER PROVIDED
ーペ
-EG
FLOWPET
-EG
Water service
MODELLS5277-4 0B, LS5377-4 0B, LS5577-40B, LS5677-40B
Oil service
MODELLS4976-4
0 , LS5076-4
0 , LS5276-4
0 , LS5376-4
0 , LS5576-4
0 , LS5676-4
0
水 用
油 用
A
B
C
D
A
B
C
D
A
B
C
D
A
B
C
D
A
B
A
B

Table of Contents

Questions and Answers:

Oval FLOWPET-EG LS4976-4 0A Series Specifications

General IconGeneral
Operating Temperature-10 to 60°C
DisplayLCD
Pipe Diameter Range15 mm to 400 mm
Flow Velocity Range0 to 10 m/s
Ambient Temperature-10 to 55°C
Outputs4-20 mA, Pulse
CommunicationModbus RTU
Power Supply24 V DC

Summary

Handling Precautions

Confirming the Nameplate

Instructions for verifying product identification and specifications on the nameplate.

Transportation Precautions

Guidelines for safely transporting the flowmeter to prevent damage.

Installation Location Precautions

Critical considerations for selecting an appropriate installation site to ensure performance.

Piping

Piping Precautions

Essential guidelines for proper and safe piping installation of the flowmeter.

Flushing the Piping Assembly

Procedure for cleaning the piping system before meter installation.

Example of Incorrect Piping

Shows common installation errors to avoid for correct operation.

How to Prevent Inductive Interferences

Methods to mitigate electromagnetic interference affecting the meter.

Wiring

Field Wiring

Guidelines for selecting and installing field wiring cables.

Hook-up Diagrams

Provides circuit diagrams for connecting the flowmeter's outputs.

Display and Controls

Operation

Operation Precautions

Crucial safety and operational advice before starting the meter.

Troubleshooting

About Error Messages

Lists error codes, their meanings, and recommended solutions.

Disassembly and Inspection

Meter Body Disassembly and Inspection

Step-by-step guide for disassembling and inspecting the meter body.

Battery Replacement and Meter Factor Setting Procedure

Battery Replacement

Details the process and precautions for replacing the internal battery.

Parameter Setting and Configuration

Covers procedures for setting, inputting, and understanding meter parameters.

General Specifications

Flow Range

Specifies the operational flow rate limits for different fluids and sizes.

Related product manuals