Detailed technical specifications for various sensor units, including materials, connections, and ratings.
General specifications for the transmitter, including power source, communication interfaces, and output capabilities.
Instructions for making power and output signal connections to the transmitter housing terminals.
Details on wiring connections between the separately mounted sensor unit and the transmitter.
Diagram showing terminal identification and descriptions for transmitter power and output signals. CAUTION on fuse and grounding.
Procedure to access the MODE SELECT menu for parameter configuration and function execution. Includes notes on Write Protect mode.
Step-by-step procedure for entering numerical data for parameters, using temperature damping as an example.
Procedure for selecting menu items and parameters, using temperature unit (Kelvin) selection as an example.
Instructions for enabling the password function and creating a 4-digit login password to safeguard settings.
Procedure for performing a probe check to diagnose transmitter circuitry issues, with corrective actions for detected faults.
Diagnostic test for the drive coil to detect problems, with results indicating acceptable or unacceptable conditions.
Diagnostic test for the transmitter to identify potential problems, with corrective actions for detected faults in various components.
Procedure for simulating analog output signals for loop checks and diagnosing faults, using a 12.00mA output example.
Procedure for simulating pulse output signals at desired frequencies for testing cable faults and performance.
Procedure for adjusting analog output levels (4mA trim) for necessary recalibration, with steps for confirmation.
Setup procedure for pulse output 1, including assignment, frequency, flow rate, low cutoff, and error state settings.
Procedure for configuring analog outputs, including assignment, upper/lower limit values, low flow cutoff, damping, and error states.
Setting up high/low alarms for flowrate, temperature, density, and total flow to quickly grasp installation conditions.
Table listing error types, descriptions, causes, and influences on output, with coping actions.
Applicable standards and specifications for TIIS explosionproof integral and separate type converters and detectors.
Applicable standards and specifications for CSA explosionproof integral and separate type converters and detectors.
Applicable standards and specifications for EAC explosionproof integral and separate type converters and detectors.
Applicable standards and specifications for NEPSI explosionproof integral and separate type converters and detectors.
Applicable standards and specifications for ITRI explosionproof integral and separate type converters and detectors.
Table detailing detector model specifications for TIIS explosionproof under various temperature classes and groups.
Table detailing detector model specifications for ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI explosionproof.
Checklist for routine inspection and maintenance of OVAL Coriolis Flowmeters, including general, grounding, sensor, and transmitter checks.
Explanation of the product code structure for Type U models (CA00A to CA080), detailing model selector charts and options.
Explanation of the product code structure for Type S stainless steel tube models, detailing model selector charts and options.
Explanation of the product code structure for Type S titanium tube models, detailing model selector charts and options.