Every OVAL product is fabricated, tested, and inspected under stringent quality control before it
leaves our factory.
To derive maximum benefit from the product, we recommend you to be well familiar with the
information and instructions given in this manual before you place it in service and retain this
manual at the field location for ready reference.
ALTI
mass
Type U/Sophisticated models: CA00A, CA001, CA003, CA006, CA010, CA015
CA025, CA040, CA050, CA080, CA100, CA150
CA15H, CA200, CA20H, CA250
Type S/Straight tube models: CS010, CS015, CS025, CS040, CS050, CS080
CSR50
Type B/Low price, general purpose models:
CB006, CB010, CB015, CB025, CB040, CB050
Transmitter : PA0K
1
Ins. No. L-740-28-E
Type S Type B
Separately mounted
transmitter
Type U
Large size
Type U
Extra low flows
Type U
Type U
Low flows

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Oval ALTI mass CA003 and is the answer not in the manual?

Oval ALTI mass CA003 Specifications

General IconGeneral
BrandOval
ModelALTI mass CA003
CategoryMeasuring Instruments
LanguageEnglish

Summary

3. SPECIFICATIONS AND PERFORMANCE

3.1 Sensor Unit General Specifications

Detailed technical specifications for various sensor units, including materials, connections, and ratings.

3.1.4 Transmitter general specifications

General specifications for the transmitter, including power source, communication interfaces, and output capabilities.

4. PRESSURE LOSSES

5. PART NAMES AND OUTLINE DIMENSIONS

5.4 Separately Mounted Transmitter

6. INSTALLATION

7. WIRING INSTRUCTIONS

7.1 Wiring Connections

Instructions for making power and output signal connections to the transmitter housing terminals.

7.1.2 Connections between separately mounted sensor unit and transmitter

Details on wiring connections between the separately mounted sensor unit and the transmitter.

7.10 Wiring Diagram

Diagram showing terminal identification and descriptions for transmitter power and output signals. CAUTION on fuse and grounding.

9. DESCRIPTION OF INCORPORATED FUNCTIONS

9.2 View Parameters and Description

Procedure to access the MODE SELECT menu for parameter configuration and function execution. Includes notes on Write Protect mode.

9.3 Parameter Value Entry

Step-by-step procedure for entering numerical data for parameters, using temperature damping as an example.

9.4 Parameter Selection

Procedure for selecting menu items and parameters, using temperature unit (Kelvin) selection as an example.

9.5 Password Function

Instructions for enabling the password function and creating a 4-digit login password to safeguard settings.

9.6 Self-diagnostic Capabilities

Procedure for performing a probe check to diagnose transmitter circuitry issues, with corrective actions for detected faults.

9.6.2 Drive coil check

Diagnostic test for the drive coil to detect problems, with results indicating acceptable or unacceptable conditions.

9.6.3 Transmitter check

Diagnostic test for the transmitter to identify potential problems, with corrective actions for detected faults in various components.

9.7 Simulated Signal Input/Output Capabilities

Procedure for simulating analog output signals for loop checks and diagnosing faults, using a 12.00mA output example.

9.7.2 Pulse output

Procedure for simulating pulse output signals at desired frequencies for testing cable faults and performance.

9.9 Analog Trim Function

Procedure for adjusting analog output levels (4mA trim) for necessary recalibration, with steps for confirmation.

9.12 Pulse Output Function

Setup procedure for pulse output 1, including assignment, frequency, flow rate, low cutoff, and error state settings.

9.13 Analog Output Function

Procedure for configuring analog outputs, including assignment, upper/lower limit values, low flow cutoff, damping, and error states.

9.16 High/Low Alarm Function

Setting up high/low alarms for flowrate, temperature, density, and total flow to quickly grasp installation conditions.

10. MAINTENANCE

10.1 Error Messages

Table listing error types, descriptions, causes, and influences on output, with coping actions.

10.4 Explosionproof Specification

Applicable standards and specifications for TIIS explosionproof integral and separate type converters and detectors.

10.4.4 CSA explosionproof

Applicable standards and specifications for CSA explosionproof integral and separate type converters and detectors.

10.4.5 EAC explosionproof

Applicable standards and specifications for EAC explosionproof integral and separate type converters and detectors.

10.4.6 NEPSI explosionproof

Applicable standards and specifications for NEPSI explosionproof integral and separate type converters and detectors.

10.4.7 ITRI explosionproof

Applicable standards and specifications for ITRI explosionproof integral and separate type converters and detectors.

10.4.8 Detector model specification table 1(TIIS explosionproof)

Table detailing detector model specifications for TIIS explosionproof under various temperature classes and groups.

10.4.9 Detector model specification table 2 (ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI explosionproof)

Table detailing detector model specifications for ATEX, IECEx, KCs, CSA, EAC, NEPSI, ITRI explosionproof.

10.6.7 Maintenance and checking

Checklist for routine inspection and maintenance of OVAL Coriolis Flowmeters, including general, grounding, sensor, and transmitter checks.

14. PRODUCT CODE EXPLANATION

14.1 Type U

Explanation of the product code structure for Type U models (CA00A to CA080), detailing model selector charts and options.

14.2 Type S

Explanation of the product code structure for Type S stainless steel tube models, detailing model selector charts and options.

14.2.2 Titanium tube type

Explanation of the product code structure for Type S titanium tube models, detailing model selector charts and options.

15. PRODUCT CODE EXPLANATION OF THE OLD PRODUCT CODE

■ Shipping Parameters

SAFETY STATEMENT ON RETURNED GOODS

REPAIR REQUEST SHEET

Related product manuals