EasyManua.ls Logo

OXE OXE-150 HP - Battery Sizing; Twin Installation

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
OXE 150/200 HP INSTALLATION MANUAL
BATTERY SIZING
The recommended battery size is based on batteries used during our tests. The specified battery has proven
good enough to ensure reliable operation so far. One battery per installed OXE outboard is rekommended.
Battery specification
Battery size 95Ah
Cranking current 850CCA
Battery cables between battery bank
Maximum total cable length between battery banks (one way) 5 m
Minimum cable area 50 mm
BATTERY CONNECTIONS
Single outboard
1. Black sleeve (negative)
2. Red sleeve (positive)
3. Hex nuts – Torque to 13.5 Nm (120 lb. in.)
4. Starting Battery
5. Ground Cable (Same Wire Size As Engine
Battery Cable) – Connect Between Negative
(–) Terminals
Twin installation

Table of Contents

Related product manuals