Troubleshooting
Problem Cause Cure
Glass is Dirty 1. Wood is wet - Use dry wood
2. Turning down air control - Do not turn down until
or damper too soon a) there is a good bed of coals
b) the wood is charred
3. Draft too low - Improper chimney height and / or diameter
- Chimney plugged or restricted, inspect and
clean
- Provide outside air for combustion
4. Door gasket leakage - Replace gasket
- Check latch
Excessive Creosote Buildup - See 1,2,3, above.
Low Heat Output 1. Wood is wet - Use dry wood
2. Fire too small - Build a larger  re
3. Draft too low - Chimney plugged or restricted, inspect and
clean
Won't Burn Overnight 1. Air control is set too high - Set control lower
2. Not enough wood - Unsplit wood is preferred for overnight burns
3. Draft too high - Excessive chimney height and/or diameter
4. Door gasket leaking - Replace door gasket.
Stove Won't Burn 1. Combustion air supply blocked - Check outside air supply for obstruction
- Check that room air cover is removed
2. Draft too low - Chimney plugged or restricted, inspect and
clean
- Chimney oversized or otherwise unsuitable,
consult Dealer