EasyManua.ls Logo

Pacific Power Source 345-AMX - Page 20

Default Icon
114 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SECTION 2 SPECIFICATIONS
12
2.1.1 INPUT POWER REQUIREMENTS (cont.)
MODEL 320-AMX
INPUT VOLTAGE AND INPUT CURRENT
The Model 320-AMX three phase input voltages, required input currents at full rated load and
recommended service input currents are stated as below.
INPUT CURRENT
(360-440 Hz optional)
INPUT
CURRENT
SERVICE
RECOMMENDED
1) 208 VAC ±10%, 47-63 Hz 11 A
rms
20 A
2) 220 VAC ±10%, 47-63 Hz 10 A
rms
20 A
3) 240 VAC ±10%, 47-63 Hz 9 A
rms
20 A
4) 220/380 VAC ±10%, 47-63 Hz 6 A
rms
15 A
5) 230/400 VAC ±10%, 47-63 Hz 6 A
rms
15 A
6) 240/416 VAC ±10%, 47-63 Hz 6 A
rms
15 A
( cost option )
7) 277/480 VAC ±10%, 47-63 Hz 5 A
rms
15 A
MODEL 345-AMX
INPUT VOLTAGE AND INPUT CURRENT
The Model 345-AMX three phase input voltages, required input currents at full rated load and
recommended service input currents are stated as below.
INPUT CURRENT
(360-440 Hz optional)
INPUT
CURRENT
SERVICE
RECOMMENDED
1) 208 VAC ±10%, 47-63 Hz 23 A
rms
40 A
2) 220 VAC ±10%, 47-63 Hz 22 A
rms
40 A
3) 230 VAC ±10%, 47-63 Hz 21 A
rms
40 A
4) 240 VAC ±10%, 47-63 Hz 20 A
rms
40 A
5) 220/380 VAC ±10%, 47-63 Hz 13 A
rms
20 A
6) 230/400 VAC ±10%, 47-63 Hz 12 A
rms
20 A
7) 240/416 VAC ±10%, 47-63 Hz 12 A
rms
20 A
( cost option )
8) 277/480 VAC ±10%, 47-63 Hz 11 A
rms
20 A

Table of Contents

Related product manuals