P2 User Manual Version 1.0
6
Outlet Setup
Power On Delay(s): The device will specify, in seconds, the delay for powering ON each outlet in order to
ensure that not all the devices connected to the P2 will power on at once.
Port Name: Specify a port name. For example, if you connect a 24-Port switch to Outlet1, you can rename
Port#1 to “24-Port-Switch”.
On/Off: Specifies the status of the port after the P2 reboots. If you reboot the P2, the status of the outlet will
depend on whether it is set to ON or OFF. If set to OFF, the P2 will reboot and the port will be OFF.
Permission: If set to “Open”, any user account created on the P2 will be able to change settings related to this
port. If more than one user is created under the “User Account Setup” menu, you can select from the drop
down menu which user can have access to make changes related to a specific port.
Auto-Ping and Reboot: If set to ON, the P2 will ping the device connected to the specific outlet every 15
seconds. If there is no response, the outlet will be rebooted, which will cause the device to reboot as well.
Ping IP: Specify the IP address of the device connected to a specific outlet if the “Auto-Ping and Reboot”
feature is used and set to ON.