Outlet Timer Setup
Timer Mode:
Select Off/Standard/Customized
Timer Starting Time:
Specify the start time for the timer. The starting time is the actual calendar date and the real-time clock. Once
a timer reaches this specified Start Time, the power outlet on/off state will change. The format for noting the
start time is as follow: “year:month:day:hour:minute:second.” For example, to change the status of the power
outlet from on to off at 7:17:27pm, on July 20
th
2012, the entry data is 12:07:20:19:17:27.
Timer Period:
Specify the timer period using the following format: “days:hours:minutes:seconds.” This is used for
applications that require the power outlet to continuously power cycle based on a specific interval. For
example, if you need to schedule power reboot for the outlet daily, the period is 24 hours. Your entry will be
00:24:00:00
Loop Count:
If you need to power cycle an outlet for a certain number of times, specify the loop count. For example, if you
schedule the timer to power cycle the outlet every 20 seconds and want to repeat it 300 times, your entry will
be 300.
Toggle Duration:
Specify the duration in seconds of the power outlet state that toggles when a new Timer Period starts. The
concept of the specification can also be viewed as Duty Cycle. This parameter is meaningful if the Timer Loop
Count is > 0. The value of this parameter should be 0 < Toggle Duration < Timer Period